Convection Fan Relay - K1

Drive voltage at J1 connector Pins 1 - 7.
1. Turn off power to oven.
2. Attach volt meter lead to E3 (neutral) connector on
relay module.
3. Attach volt meter lead to E4 (CVF) connector on
relay module.
4. Turn on power and touch convection pad.
5. If 120VAC is indicated convection fan relay is
operating.

Oven Light Relay - K10

Drive voltage at J1 connector Pins 1 - 4.
1. Turn off power to oven.
2. Attach voltmeter lead to E3 (neutral) connector on
relay module.
3. Attach voltmeter lead to E17 connector on relay
module.
4. Turn on power and touch oven light pad.
5. If 120 VAC is indicated oven light relay is operating.
RS2320001 Rev. 2
DISCONNECT POWER BEFORE SERVICING, UNLESS TESTING REQUIRES IT.

Panel Light Relay - K11

Drive voltage indicated at J1 connector pins 1 - 8.
1. Turn off power to oven.
2. Attach voltmeter lead to E3 (neutral) connector on
relay module.
3. Attach voltmeter lead to E14 (Panel LT) connector on
relay module.
4. Turn on power and touch panel light pad.
5. If 120 VAC is indicated the panel light relay is
operating.

Door Lock Relay - K3

Double line break relay okay. Drive voltage at J1
connector Pins 5 - 4.
1. Turn off power to oven.
2. Attach voltmeter lead to E3 (neutral) connector on
relay module.
3. Attach voltmeter lead to E8 connector on relay
module.
4. Turn on power and program cleaning cycle
operation.
5. Two indications will be present during this test.
a.
120 VAC will be present when the lock
assembly is being engaged.
b.
0 VAC is indicated when the door is locked and
cleaning cycle is operational.
TRANSFORMER/RELAY
MODULE
26