If you purchased two ICL-F arrays separately and now want to
turn them into a ICL-F-DUAL array, you will also need an ICL-F-
UP joining kit..
The first assembly step is to remove the top of both modules. To
remove the top, remove the eight machine screws from each
side of the cabinet and lift the top and its mounting brackets out
of the cabinet as shown.
The next step is to install the two heavy joining plates They will
be packed with the hardware if you ordered an ICL-F-DUAL.
Note: The graphics that follow show the two joining plates
mounted in one cabinet. In actual practice, it is better to
mount one plate in one cabinet and the other in the second
cabinet. They should be attached to the side where the small
db15 signal cable connector is located. This reduces the
possibility of damaging the connector while sliding the two
cabinets together.
Use the mounting bracket machine screws you removed to install
the two heavy joining plates. Tighten the screws lightly. The join-
ing plates need to be a little loose to slide easily into the other
cabinet.
All manuals and user guides at all-guides.com
5
IC Live Users Manual, ICL-F & ICL-F-DUAL
Attach the eavy joining plate to the rear of the cabinet using the
machine screws provided with the hardware. See below. Tighten
the screws loosely to allow a little movement while joining the two
modules.
Plug one end of the flat wire signal cable into the socket provided.
It only goes into the socket one way and the cable is reversible. It
does not matter which end goes into which module. Using a small
Phillips screw driver, secure the connector with two 4-40 Phillips
head screws (supplied). Make sure the connector is fully seated.
You should hear a click when they seat. See below.