Download Print this page

Assembly; Operation; Technical Data; Spare Part - Hans Grohe Focus E Series Assembly Instructions Manual

Advertisement

Important! The fitting must be installed, flushed
and tested after the valid norms!

Assembly

1
Flush through the supply pipes.
2
Place the mixer including the sealing
washer in position on the sink.
3
Slip the plastic washer, the slide washer,
the metall washer and collar over the hoses
and threaded base and tighten the collar nut
by hand. If there is not enough space,
please use only the slide washer and the
metal washer without the plastic washer.
4
Tighten screws.
5
Connect the supply pipes to the isolation
valves; cold right - hot left.
The hot and cold supplies must be of equal
pressures.

Operation

The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.

Technical Data

Operating pressure:
Recommended operating pressure:
MPa
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow:
English
max. 1 MPa
0,1 – 0,5
1,6 MPa
max 80° C
65° C
11 l/min 0,3 MPa
Hansgrohe single lever mixers can be used
together with hydraulically and thermically
controlled continuous flow heaters if the flow
pressure is at least 0,15MPa.
To adjust the hot water limiter on single lever
mixers, please see page 7.
No adjustment is necessary when using a
continuous flow water heater.
Spare parts see page 4
1
handle E
1.1 screw cover
2
handle S
3
flange
4
nut
5
cartridge cpl.
6
aerator cpl.
7
fixing set
8
connection hose 600 mm 3/8"
9
connection hose 600 mm
10
seal
31795000
96338000
31797000
97995000
97996000
92730000
13913000
95049000
96556000
97997000
98702000
5