  • Page 1 955751.book : t95575.fm Seite 1 Mittwoch, September 20, 2000 10:10 AM Avensys Exposed Single Lever Mixer 33 389 33 396 Installation Instructions and Operating Guide Please leave this document with the user after finishing installation! 95.575.131/ÄM 30 222/09.00...
  • Page 2 kl955751.fm Seite 1 Montag, August 21, 2000 3:11 PM Table Of Contents Installation Dimensions (mm) 33 389 33 396 Wallplugs Handshower Screws Plug Filter Escutcheons Backplate Mixer Body Outlet Nipple Filter Threaded Ring Flexible Hose Flow Limiter Shower Rail...
  • Page 3 kl955751.fm Seite 2 Montag, August 21, 2000 3:11 PM Spare Parts...
  • Page 4: Table Of Contents

    Dear Customer, Technical Data ....6 Thank you for choosing a GROHE product. Please follow these instructions carefully Installation ..... . . 7 and you will enjoy many years of reliable Exposed Installation.
  • Page 5: Technical Data

    955751.book : i95575gb.fm Seite 6 Mittwoch, September 20, 2000 10:10 AM Technical Data Functioning Principle New Water Regulations This Avensys mixing valve is a single lever This GROHE-product should be installed to mixer with ceramic cartridge. Lifting the lever comply with the New Water Regulations opens water flow.
  • Page 6: Installation

    955751.book : i95575gb.fm Seite 7 Mittwoch, September 20, 2000 10:10 AM Installation Exposed Installation 1.Loosely screw on nut (A1) with com- pression ring (A2), see Fig. [2]. The single lever shower mixer can be in- stalled in two different ways. The mixing outlet can be at the bottom for use with a handshower or at the top for use with a headshower.
  • Page 7 955751.book : i95575gb.fm Seite 8 Mittwoch, September 20, 2000 10:10 AM Installation 6.Mark the holes in the backplate for wall- 9. Slide the escutcheons (H) over the plugs, see Fig. [4]. supply pipes, see Fig. [7]. 7.Drill the holes (6mm) for the wallplugs (F) and fit them into the wall, see Fig.
  • Page 8: Maximum Hot Water Limit Setting

    955751.book : i95575gb.fm Seite 9 Mittwoch, September 20, 2000 10:10 AM Installation Shower Hose Connection Pipe Connection 1.Close free outlet with plug (K), see 1.Close free outlet with plug (K), see Fig. [9]. Fig. [10]. ° 2.Thread the outlet nipple (L) with the O-ring seal into the mixer body outlet.
  • Page 9 955751.book : i95575gb.fm Seite 10 Mittwoch, September 20, 2000 10:10 AM Installation Maximum Hot Water Limit Setting 5.Remove temperature limiter (M) and, depending on the maximum water On delivery, the adjustable temperature temperature required, turn clockwise limiter (fitted as standard) is inoperative. (to increase temperature) or anticlock- wise (to reduce temperature) and refit, On applications requiring limiting the mixer...
  • Page 10 Ceramic Cartridge 1.Shut off hot and cold water supply! 2.Lever out plug (O), see Fig. [13]. Check, clean and if necessary replace parts. Only genuine GROHE replacement parts must be used. 3.Remove set screw (P) with 3mm socket spanner 4.Pull off lever (R).
  • Page 11: Care

    Care We want to ensure that you get long-lasting your fitting dull and scratched. As the for- satisfaction and pleasure from your GROHE mulations of commercially available cleaning fitting. Therefore, please read the following agents frequently change, we cannot gua-...
  • Page 12: Guarantee

    Fax: 0208 / 594 88 98 AG & Co. KG © 2000 Friedrich Grohe Friedrich Grohe AG & Co. KG · P.O. Box 1361 · 58653 Hemer/Germany Tel. (0) 23 72 / 93 - 0 · Fax: (0) 23 72 / 93 13 22...