Page 2
CALIFORNIA PROPOSITION 65 WARNING: 10. If basin is fiberglass, concrete must be poured on anti-flotation ring to prevent basin from This product and related floating up. Amount of concrete varies with type accessories contain chemicals known to the of ground in which basin is installed. Where State of California to cause cancer, birth defects or other reproductive harm.
Page 3
STARTING SYSTEM CAUTION: KEEP HANDS AND FINGERS 1. Open gate valves on discharge piping. AWAY FROM GRINDER IMPELLER WHEN 2. Set pump switches at control box at auto MAKING THIS CHECK. position and turn on power. Fill sump with water If 3 phase rotation is wrong, interchange any until controls start pump.
Page 4
PARTS INCLUDED IN RAIL PACKAGE GUIDE AND MOUNTING PLATE FOR PUMP RAIL SUPPORT YOKE YOKE SUPPORT MOUNTING SLEEVE DISCHARGE CASTING (4 SQ. HD. SET SCREWS RIGHT AND LEFT HAND 7/16-14 X 3/4” LG.) REQUIRED FOR DUPLEX SYSTEM UPPERHOLD-DOWN BRACKET (4 SQ. HD. SET SCREWS 7/16-14 X 1”...
Page 5
SIMPLEX INSTALLATION FIBERGLASS BASIN CONCRETE BASIN FLASHING ALARM LIGHT FLASHING ALARM LIGHT SIMPLEX CONTROL BOX 20 x 16 x 7 FLASHING ALARM LIGHT SIMPLEX CONTROL BOX SIMPLEX CONTROL BOX CONTROL BOX MTG. PLATE 6 x 6 MOUNTING PEDESTAL CONTROL BOX MTG. PLATE 6 x 6 WIRING PEDESTAL VALVE SHUT-OFF 6 x 6 WIRING PEDESTAL...
Page 6
DUPLEX INSTALLATION FIBERGLASS BASIN CONCRETE BASIN FLASHING ALARM LIGHT FLASHING ALARM LIGHT - RED DUPLEX CONTROL BOX DUPLEX CONTROL BOX 6" x 6" MOUNTING PEDESTAL 6 x 6 WIRING PEDESTAL VALVE SHUT-OFF HANDLE 6" 6" 12" 12" VALVE SHUT-OFF HANDLE 48"...
Page 7
RWG Series Rail System Parts List Part Numbers Standard Hazardous Location Ref. Description Req. RWGRH-300 RWGLH-300 RWGXRH-300 RWGXLH-300 Guide – Upper Rail 22610C000 22610C000 22610C000 22610C000 Eye Bolt – 3/8"-16 UNC x 1" Eye 21929A002 21929A002 21929A002 21929A002 Clevis, Chain Shackle – 1/4" Screw Type 22417A001 22417A001 22417A001...
Warranty is effective only if Pentair Myers authorized control panels are used. All seal fail and heat sensing devices must be hooked up, functional and monitored or this warranty will be void. Pentair Myers will cover only the lower seal and labor thereof for all dual seal pumps. under no circumstance will Pentair Myers be responsible for the cost of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the factory or an authorized Pentair Myers service facility.
Need help?
Do you have a question about the MYERS WG30 and is the answer not in the manual?
Questions and answers