Parameters Setting - Baxi LUNA 3 COMFORT AIR Series Installers And Users Instructions

High efficiency wall-mounted gas-fired boilers
Hide thumbs Also See for LUNA 3 COMFORT AIR Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 39
To access the Parameters setting mode proceed as follows:
• press, for at least 3 seconds, the ip button;
• press first the
button then press together the
When the function is activated, the display shows "F01" with the value of the selected parameter.

parameters setting

• Press +/-
buttons for scrolling parameters;
• Press +/-
buttons to change the single parameter value;
nota: the value is automatic saved after about 3 seconds.
(Do not press any button until the value is beginning to flash again).
Description of parameter
F01
Type of gas boiler
10 = sealed chamber
F02
Type of gas
00 = natural (metane) - 01 = LPG
F03
Hydraulic system
00 = instantaneous appliance
F04
Programmable relay 1 setting
2 = zone system (See Service instructions)
F05
Programmable relay 2 setting
13 = Cool function (See Service instructions)
F06
External sensor programmable input setting
(See Service instructions)
F11...F12
Manufacture information
F13
CH max. heating output
F14
D.H.W. max. heating output (0-100%)
F15
CH min. heating output
F16
Maximum temperature setpoint setting
00 = 85°C - 01 = 45°C
F17
Pump overrun time
(01-240 minutes)
F18
Minimum burner pause
in central heating mode (01-10 minutes) - 00=10 seconds
F19
Manufacture information
F20...F22
Manufacture information
F23
Maximum D.H.W. setpoint
F24
Not used
F25
Lack of water safety device
F26...F29
Manufacture information (only read parameters)
F30
Manufacture information
F31
Manufacture information
F32...F41
Diagnostics (See Service instructions)
last
Controller stop function activation
parameter
(See Service instructions)
WarninG: do not modify the values of the "Manufacture information" parameters.
inStructionS Pertaining to the inStaller
20. parameters setting
button.
(0-100%)
(0-100%)
64
Default value
250 Fi
10
00 o 01
00
02
04
00
00
100
100
00
00
03
03
07
00
60
35
00
--
10
30
--
00
310 Fi
- GB
926.427.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Luna 3 comfort air 310 fiLuna 3 comfort air 250 fi