Code
Defini on
19
Electrical Grounding
Outgoing Water
32
Temperature Sensor
Heat Exchanger Outgoing
33
Temperature Sensor
Combus on Air
34
Temperature Sensor
Outside temperature
41
thermistor (outdoor
models only)
Inlet water temperature
51
thermistor
Modula ng Solenoid Valve
52
Signal
61
Combus on Fan
65
Water Flow Control
70
PC Board
71
Solenoid Valve Circuit
72
Flame Sensing Device
79
Water Leak Detected
Scale Build-up in Heat
LC #
Exchanger (when checking
(LC0,
maintenance code history,
LC1,
"00" is subs tuted for
LC2,...)
"LC")
Maintenance has been
FF
performed
No
Nothing happens when
code
water flow is ac vated.
38
Remedy
Check all components for electrical short.
Check sensor wiring for damage.
Measure resistance of sensor.
Clean sensor of scale build-up.
Replace sensor.
Check for restric ons in air flow around unit and vent terminal.
Check sensor wiring for damage.
Measure resistance of sensor.
Clean sensor of scale build-up.
Ensure fan blade is ght on motor sha and is in good condi on.
Replace sensor.
Check sensor wiring for damage.
Measure resistance of sensor.
licensed
Clean sensor of scale build-up.
professional
Replace sensor.
only
Check modula ng gas solenoid valve wiring harness for loose or damaged terminals.
Measure resistance of valve coil.
Ensure fan will turn freely.
Check wiring harness to motor for damaged and/or loose connec ons.
Measure resistance of motor winding.
The water flow control valve has failed to close during the bath fill func on. Immediately turn
off the water and discon nue the bath fill func on. Contact a licensed professional to service
the appliance.
Check PC board DIP switches for correct posi on.
Check the connec on harness at the connec on on the PC board.
Replace PC board.
Replace the PC Board.
Replace PC Board
Water has been detected at the bo om of the unit. Turn off water supply. Check all plumbing
internally for leakage.
LC0~LC9 indicates that there is scale build up in the heat exchanger and that the heat
exchanger needs to be flushed to prevent damage. Refer to the flushing instruc ons in the
manual. Hard water must be treated to prevent scale build up or damage to the heat
exchanger.
To operate the water heater temporarily un l the heat exchanger can be flushed, push the On/
Off bu on on the temperature controller 5 mes. Repeated LC codes will eventually lockout
the water heater.
Please call Rinnai technical department.
Indicates a licensed professional performed maintenance or corrected an issue.
Clean inlet water supply filter.
On new installa ons ensure hot and cold water lines are not reversed.
Verify you have at least the minimum flow rate required to fire unit.
Check for cold to hot cross over. Isolate circula ng system if present. Turn off cold water to the
unit, open pressure relief valve; if water con nues to flow, there is bleed over in your plumbing.
licensed
Verify turbine spins freely.
professional
Measure the resistance of the water flow control sensor.
only
If the display is blank and clicking is coming from the unit, disconnect the water flow servo
motor (GY, BR, O, W, P, BL, R). If the display comes on then replace the water flow servo
motor.