GiBiDi SC230 Electrical Connections
GiBiDi SC230 Electrical Connections

GiBiDi SC230 Electrical Connections

Electronic control unit
Hide thumbs Also See for SC230:

Advertisement

SC
SC230 (AS05710-
AS05711
)
Apparecchiatura elettronica
SCHEMA ELETTRICO E COLLEGAMENTI
Electronic control unit
I
UK

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SC230 and is the answer not in the manual?

Questions and answers

Summary of Contents for GiBiDi SC230

  • Page 1 SC230 (AS05710- AS05711 Apparecchiatura elettronica SCHEMA ELETTRICO E COLLEGAMENTI Electronic control unit ELECTRICAL CONNECTIONS...
  • Page 2 SC230 I-UK SCHEMA ELETTRICO / ELECTRICAL CONNECTIONS 9 9 1 G:B:D:055G3 START PHOTO F0.5A IND. SENSOR SAFETY DL10 STOP-SAFETY F0.5A DL10 SENSORE FINECORSA CHIUDE CLOSING LIMIT SWITCH SENSOR SENSORE FINECORSA APRE OPENING LIMIT SWITCH SENSOR EXTERNAL CAPACITOR 14 15 16 17 18 19...
  • Page 3 SC230 I-UK COLLEGAMENTO ALIMENTAZIONE / POWER SUPPLY CONNECTION NEUTRAL PHASE 230Vac INTERRUTTORE MAGNETOTERMICO INTERRUTTORE DIFFERENZIALE OVERCURRENT CIRCUIT BREAKER RESIDUAL-CURRENT DEVICE NEUTRAL PHASE COLLEGAMENTO DI TERRA / EARTH CONNECTION COLLEGAMENTO MOTORE / MOTOR CONNECTION 5 6 7 5 6 7...
  • Page 4 SC230 I-UK INSTALLAZIONE SENZA RALLENTAMENTI / INSTALLATION WITHOUT DECELERATIONS STOP STOP APERTURA CHIUSURA CLOSING OPENING INSTALLAZIONE CON RALLENTAMENTI / INSTALLATION WITH DECELERATIONS STOP STOP INIZIO RALLENTAMENTO IN CHIUSURA INIZIO RALLENTAMENTO IN APERTURA DECELERATION START IN CLOSING DECELERATION START IN OPENING...
  • Page 5 SC230 I-UK COLLEGAMENTO CONDENSATORE / CAPACITOR CONNECTION EXTERNAL EXTERNAL CAPACITOR CAPACITOR 14 15 16 17 18 19 5 6 7 8 9 10 11 12 13 5 6 7 8 9 10 11 12 13 230Vac 230Vac CONDENSATORE CAPACITOR COLLEGAMENTO LAMPEGGIANTE / FLASHING LIGHT CONNECTION...
  • Page 6 SC230 I-UK COLLEGAMENTO FOTOCELLULE / PHOTOCELLS CONNECTION 4 11 ( AU02000 SINCRONIZZATE / SYNCHRONIZED ) 8 9 10 11 12 13 14 15 16 17 18 19 COLLEGAMENTO FOTOCELLULE CON TEST / PHOTOCELLS CONNECTION WITH TEST ( AU02000 SINCRONIZZATE / SYNCHRONIZED )
  • Page 7 SC230 I-UK COLLEGAMENTO “DISPOSITIVO DI SICUREZZA” NC / NC “SAFETY DEVICE” CONNECTION 4 15 8 9 10 11 12 13 COLLEGAMENTO “DISPOSITIVO DI SICUREZZA” 8K2 / “SAFETY DEVICE” CONNECTION 4 16 8 9 10 11 12 13 COLLEGAMENTO “DISPOSITIVO DI SICUREZZA” NC AGGIUNTIVO / ADDITIONAL NC “SAFETY DEVICE” CONNECTION...
  • Page 8 SC230 I-UK COLLEGAMENTO STOP / STOP CONNECTION 4 31 DIP SWITCH 10 = OFF 8 9 10 11 12 13 COLLEGAMENTO SPIA DI SEGNALAZIONE / WARNING LIGHT CONNECTION 4 20 24Vac 3W MAX 14 15 16 17 18 19 COLLEGAMENTO SENSORE GIRI MOTORE / MOTOR RPM SENSOR...
  • Page 9 SC230 I-UK IMPOSTAZIONE DI DEFAULT DIP SWITCH SW1 / DIP SWITCH SW1 DEFAULT SETTINGS MORSETTO 12 COME COSTA 8k2 / TERMINAL 12 AS 8k2 SAFETY EDGE MORSETTO 12 COME STOP 8k2 / TERMINAL 12 AS 8k2 STOP SENSORE GIRI MOTORE ABILITATO / MOTOR RPM SENSOR ENABLED...
  • Page 10 SC230 I-UK TRIMMER “FORCE” MOVEMENT SPEED : - THRUST FORCE: MOVEMENT SPEED : 100% - THRUST FORCE: VELOCITA’ ANTA : 50% - FORZA DI SPINTA : 25% VELOCITA’ ANTA : 100% - FORZA DI SPINTA : 25% MOVEMENT SPEED : 10...
  • Page 11 SC230 I-UK TRIMMER “SLOW” RALLENTAMENTO RALLENTAMENTO DECELERATION DECELERATION MOVEMENT SPEED : - THRUST FORCE: MOVEMENT SPEED : 100% - THRUST FORCE: VELOCITA’ ANTA : 50% - FORZA DI SPINTA : 25% VELOCITA’ ANTA : 100% - FORZA DI SPINTA : 25%...
  • Page 12 GI.BI.DI. S.r.l. Via Abetone Brennero, 177/B 46025 Poggio Rusco (MN) - ITALY Tel. +39.0386.52.20.11 Fax +39.0386.52.20.31 E-mail: info@gibidi.com Numero Verde: 800.290156 w w w . g i b i d i . c o m...