  • Page 1 F4 PLUS Apparecchiatura elettronica F4 PLUS (AS05850) ISTRUZIONI PER L’INSTALLAZIONE Electronic control unit INSTRUCTIONS FOR INSTALLATIONS...
  • Page 2: Caratteristiche Tecniche

    Dip switch di esclusione degli ingressi FINECORSA e FOTOCELLULA, se non utilizzati. Ÿ Grazie per avere scelto GIBIDI. LEGGERE ATTENTAMENTE QUESTO MANUALE PRIMA DI PROCEDERE ALL’INSTALLAZIONE. AVVERTENZE: Questo prodotto è stato collaudato in GI.BI.DI. verificando la perfetta corrispondenza delle caratteristiche alle direttive vigenti.
  • Page 3: Avvertenze Per L'installazione

    F4 PLUS 3 - AVVERTENZE PER L’INSTALLAZIONE • Prima di procedere con l’installazione bisogna predisporre a monte dell’impianto un interruttore magneto termico e differenziale con portata massima 10A. L’interruttore deve garantire una separazione omnipolare dei contatti, con distanza di apertura di almeno 3 mm.
  • Page 4 F4 PLUS 5 - COLLEGAMENTI ELETTRICI: MORSETTIERE Morsetto Posizione Segnale Descrizione Collegamento motore 1 (apertura) Collegamento motore 1 (comune) Collegamento motore 1 (chiusura) Collegamento motore 2 (apertura) Collegamento motore 2 (comune) Collegamento motore 2 (chiusura) Uscita (FASE) LUCE DI CORTESIA se dip9=off – Uscita fissa per LAMPEGGIATORE se dip9=on Uscita (NEUTRO) LUCE DI CORTESIA se dip9=off –...
  • Page 5: Fusibili Di Protezione

    F4 PLUS 6 - FUSIBILI DI PROTEZIONE Descrizione Posizione Valore Tipo Protegge la scheda elettronica e i motori. RAPIDO Protegge la scheda elettronica e gli accessori. 160mA RAPIDO 7 - LED DI SEGNALAZIONE Segnale Colore Descrizione Sempre acceso. Si spegne quando viene raggiunto il FINECORSA DI...
  • Page 6 F4 PLUS 8 - DIP SWITCH DIP1 Le impostazioni vengono memorizzate durante la fase di riposo (cancello chiuso). Le impostazioni di DEFAULT sono evidenziate con lo sfondo della casella in grigio Descrizione Funzione Stato Quando viene intercettata la fotocellula, sia in apertura che in chiusura, viene bloccato il moto del cancello fino alla liberazione della fotocellula.
  • Page 7 F4 PLUS 8 - DIP SWITCH DIP1 Descrizione Funzione Stato Esclude l'ingresso finecorsa. FINE CORSA APRE DIP 4 MOTORE 1 Abilita l'ingresso finecorsa. Esclude l'ingresso finecorsa. FINE CORSA CHIUDE DIP 5 In caso di impianto con un solo motore ed MOTORE 1 Abilita l'ingresso finecorsa.
  • Page 8 F4 PLUS 9 - DIP SWITCH DIP2 Descrizione Funzione Stato DIP2_3 NON UTILIZZATI DIP2_4 10 - REGOLAZIONE TRIMMER Trimmer Default Descrizione Ruotando in senso orario regola (aumenta) la coppia dei motori dal 25% al 100%. FORCE Per i primi 3 sec. Interviene lo spunto con potenza 100%.
  • Page 9 F4 PLUS DESRCIZIONE MENU ( A ) 12 - RIEPILOGO SEGNALAZIONI DA LAMPEGGIATORE Dispositivo Ssegnalazione Effetto Costa intercettata prima del moto 3 lampeggi lenti Porta bloccata NOTE...
  • Page 10 F4 PLUS Dichiarazione di conformità CE Il fabbricante: GI.BI.DI. S.r.l. Via Abetone Brennero, 177/B, 46025 Poggio Rusco (MN) ITALY Dichiara che i prodotti: APPARECCHIATURA ELETTRONICA F4PLUS Sono conformi alle seguenti Direttive CEE: Direttiva LVD 2006/95/CE e successive modifiche; • • Direttiva EMC 2004/108/CE e successive modifiche;...
  • Page 11: Technical Specifications

    DIP switch to disable the LIMIT SWITCH and PHOTOCELL inputs if not used. Ÿ Thank you for choosing GIBIDI. CAREFULLY READ THESE INSTRUCTIONS BEFORE PROCEEDING WITH INST ALLATION. WARNINGS: This product has been tested by GI.BI.DI. for full compliance with the requirements of the directives in force. GI.BI.DI. S.r.l. reserves the right to change the technical data without prior notice in relation to product development.
  • Page 12: Installation Warnings

    F4 PLUS 3 - INSTALLATION WARNINGS • Before proceeding with installation, fit a differential magnetothermal switch with a maximum capacity of 10A upstream of the system. The switch must guarantee omnipolar separation of the contacts with an opening distance of at least 3mm.
  • Page 13 F4 PLUS 5 - ELECTRICAL CONNECTIONS: TERMINAL BOARDS Terminal Position Signal Description Motor 1 connection (opening) Motor 1 connection (common) Motor 1 connection (closing) Motor 2 connection (opening) Motor 2 connection (common) Motor 2 connection (closing) COURTESY LIGHT output (PHASE) if DIP9=OFF - Fixed output for FLASHLIGHT if...
  • Page 14: Protection Fuses

    F4 PLUS 6 - PROTECTION FUSES Description Position Value Type Protects the circuit board and the motors. FAST Protects the circuit board and the accessories. 160mA FAST 7- WARNING LEDs Signal Colour Description Always on. Goes off when the CLOSING LIMIT SWITCH of motor 2 is FCCM2 reached.
  • Page 15 F4 PLUS 8 - DIP SWITCH DIP1 The settings are stored during the rest phase (gate closed). The default settings are highlighted in the boxes with grey background. Description Function Status When the photocell is intercepted during both opening and closing, the gate motion is locked until the photocell is freed.
  • Page 16 F4 PLUS 8 - DIP SWITCH DIP1 Description Function Status Disables the limit switch input MOTOR 1 OPENING DIP 4 LIMIT SWITCH Enables the limit switch input Disables the limit switch input MOTOR 1 CLOSING DIP 5 In the case of a system with only one motor...
  • Page 17: Trimmer Adjustment

    F4 PLUS 9 - DIP SWITCH DIP2 DIP2_3 NOT USED DIP2_4 10 - TRIMMER ADJUSTMENT Trimmer Default Description Turning clockwise adjusts (increases) the motor torque from 25% to 100%. In the first 3 seconds, a FORCE pick-up with 100% power occurs.
  • Page 18 F4 PLUS DESRCIZIONE MENU ( A ) 12 - SUMMARY OF FLASHLIGHT SIGNALLING Device Signalling Effect Frame intercepted before motion 3 slow flashes Gate/door locked NOTES...
  • Page 19 F4 PLUS EC Declaration of Conformity The manufacturer: GI.BI.DI. S.r.l. Via Abetone Brennero, 177/B, 46025 Poggio Rusco (MN) ITALY declares that the product: F4PLUS ELECTRONIC CONTROL UNIT is in conformity with the following EEC Directives: LVD Directive 2006/95/EC and subsequent amendments;...
  • Page 20 GI.BI.DI. S.r.l. Via Abetone Brennero, 177/B 46025 Poggio Rusco (MN) - ITALY Tel. +39.0386.52.20.11 Fax +39.0386.52.20.31 E-mail: info@gibidi.com Numero Verde: 800.290156 w w w . g i b i d i . c o m...