Diagnostic sequence – Stage 10
If the water level in the float reservoir drops to an unacceptable level, the WTR LED will go out, shutting the ice
machine off. Also, the BT LED will come on, preventing the ice machine from restarting for twenty minutes. If water is
restored, the WTR LED will come back on and flash to alert the technician that water to ice machine has been lost.
The ice machine will then restart at the end of the 20 minute time delay. The flashing WTR LED can be cleared by
pressing the reset button.
INPUT
POWER
G
B
W
COMPRESSOR
C
T.O.L.
RED
WHITE
GRD
FAN
BLACK
BLACK
M
BLACK
R
M
ORANGE
S
L
S
BLACK
HIGH PRESSURE
SAFETY SWITCH
START
GEAR MOTOR
RELAY
START
4
2
BLACK
3
YELLOW
RUN
T.O.L.
START CAP.
GEAR MOTOR
START
RED
RUN
T.O.L.
T400A/W, MCD400A/W, R400A/W, MFD400A/W, D400A/W Ice Machines
WATER
SENSOR
WHITE
WHITE
RED
BLACK
1
BLACK
BLACK
BISON GEARMOTOR
OR
LINIX GEARMOTOR
PWR
RESET
GRD
DR
L1
L1
C
L2
20M
CONTROL
L2
BOARD
60M
L2
L2
2ND
L2
WTR
B-T
COMPRESSOR
B-E
FAN
DRIVE
COMPRESSOR
SWITCH
BIN SIGNAL
FROM DISPENSER
BIN T-STAT
JUNCTION BOX
(MCD400A/WVS series –
blk wire is on 24V)
RED
RED