3. ELECTRICAL EQUIPMENT (standard system)
Left-hand Fold operator
Right-hand Fold operator
Photocells
MASTER control board (controls all accessories)
SLAVE control board (for 2nd leaf only)
Key operated
push-button
Receiver
12 Vdc flashing lamp
Notes: 1) Do not extend the operator connecting cables
2) To lay electric cables, use adequate rigid and/or
flexible tubes.
3) Always separate low voltage connection cables from
those operating at 230 Vac. To prevent any interference
whatever, use separate sheaths.
Leaf 1
Master card
Leaf 2
Master card
In double-leaf applications, the Master card always
commands leaf 1. In case of incorrect electrical set-up, leaf 1
can be commanded by the Slave card, and leaf 2 by the
Master card. For programming, refer to chapter 14.
Leaf 1 is always the leaf that starts first on opening and is
delayed on closing.
4. INSTALLING THE AUTOMATED SYSTEM
4.1.
PRELIMINARY CHECKS
To ensure safety and an efficiently operating automated system,
make sure the following conditions are observed:
The structure of the gate must be suitable for being
automated. In particular, check that the structure is sufficiently
Fig. 3
Leaf 2
Slave card
Leaf 1
Slave card
Fig. 4
14
strong and rigid, and that its dimensions and weight conform
to those indicated in the technical specifications.
Make sure that the leaves move uniformly and correctly,
without any irregular friction during their entire travel.
Make sure that the hinges are in good condition.
Check if the mechanical stops of the limit-switches are fitted.
We advise you to have any metalwork carried out before the
automated system is installed.
4.2.
INSTALLATION DIMENSIONS
Establish the installation position of the operator by referring to Fig.
5.
Carefully check that the distance between the leaf hinge and
any obstacles (wall, fencing, etc.) is greater than or equal to
I referring to the selected opening angle, so that
minimum dimension
it does not interfere with the opening movement of the operator.
Fig. 5
B
D
A
Z
I
min.
Tab. 2/a
Opening at 90° (D
D
30
90÷240
40
90÷240
60
90÷220
80
90÷210
100
90÷210
120
90÷180
140
90÷170
160
90÷160
180
90÷140
200
90÷100
205
Tab. 2/b
Opening at 110° (D
D
30
140÷250
40
140÷250
60
150÷240
80
160÷200
100
165÷180
120
165
• Dimensions in mm
= 205 mm)
max
B
I
min
400
400
400
400
400
400
400
400
400
400
90
400
• Dimensions in mm
= 120 mm)
max
B
I
min
500
500
500
500
500
500
• Dimensions in mm
Z=80 mm
max
90°
90°
90°
90°
90°
90°
90°
90°
90°
90°
90°
max
110°
110°
110°
110°
110°
110°