Leaf max weight (kg) struck when moving or when open. Operator overall dimensions LxHxD (mm) see fig.2 The FOLD automated system was designed and built for controlling Length of operator power cable 0,7 m vehicle access. Do not use for any other purpose.
Page 4
(wall, fencing, etc.) is greater than or equal to I referring to the selected opening angle, so that minimum dimension it does not interfere with the opening movement of the operator. Left-hand Fold operator Fig. 5 • Dimensions in mm Right-hand Fold operator...
Page 5
ENGLISH 4.3. INSTALLATION STEPS The Fold operator is available in 2 versions, designed for installation according to leaf opening direction: the F DX for installation on the right (Fig.6 - RH) or the F SX for installation on the left(Fig.6 - LH).
Page 6
ENGLISH MIND MASTER AND MIND SLAVE CONTROL BOARDS WARNINGS Important: Before attempting any job on the control boards (connections, maintenance), cut out electrical power and the support batteries. - Install, upstream of the system, a differential thermal breaker with adequate tripping threshold. - Always separate 230VAC power cable from control and safety cables (push-buttons receiver, photocells, etc.).
Page 7
ENGLISH MASTER CARD TECHNICAL SPECIFICATIONS MASTER SLAVE CARDS COMMON CHARACTERISTICS Power supply 12Vac Transformer characteristics Primary 230 Vac - Secondary Batteries hermetic Pb 12Vdc 1.2Ah - dimensions 96x46x50 12 Vac - 16VA Enclosure protection class IP 55 Accessories max. load at 24 Vdc 150 mA Absorbed power 16 VA...
Page 8
ENGLISH 11.1. Connection of photocells and safety devices Before connecting the photocells (or other devices) we advise Opening/closing safety devices you to select the type of operation according to the movement zone to be protected (see fig.15). Opening safety devices: they operate only during the gate opening movement and, therefore, they are suitable for protecting the zone between the opening leaves...
Page 9
ENGLISH Connection of 1 pair of photocells for closing Connection of 1 pair of photocells for opening — — Fig. 20 Fig. 21 Connection of a pair of closing photocells, one for opening Connection of 2 pairs of photocells for closing and the other for opening/closing —...
Page 10
ENGLISH OPEN B - "RELEASED LEAF OPENING" (terminal 2) OPEN command: 11.5. J4 Connector - Battery connection any device (e.g. push-button) which, by closing a contact, Connect the operator support battery (fig. 14) to this provides an opening and/or closing pulse for the gate leaf connector.
Page 11
ENGLISH J4 Battery J3 J2 Transf. Motor F1 Batt. Fig. 28 Diagnostics - If you press push-button P1, LED A lights up; use push- button P2 to select the required logic as shown in table 5. The “P” LED (see fig. 21) has a diagnostic function. There are -If you press push-button P1 again, LED B lights up;...
ENGLISH As an alternative to the open, allow the leaf to reach its 15. AUTOMATION TEST opening stop point. 3 rd OPEN - Leaf 2 opening deceleration start. When installation has been completed, run a careful functional check of the automated system and all accessories connected 4 th OPEN - Leaf 2 opening stop and immediate start of to it, especially the safety devices.
Page 14
Les descriptions et les illustrations du présent manuel sont fournies à titre indicatif. GENIUS se réserve le droit d’apporter à tout moment les modifications qu’elle jugera utiles sur ce produit tout en conservant les caractéristiques essentielles, sans devoir pour autant mettre à...