Advertisement

LOAD
ACCEPTABLE
Tensile Strength (UTS): 10,000-lbf (44kN)
Working Load (WLL): 1.000 lbs (454kg)
Maximum Capacity: One worker, 310 lbs (140kg)
Weight: 2.0-lbs (949g)
Regulatory Compliance: ANSI Z359.1-2007, ANSI Z359.7-
2011, OSHA 1910.66 , 1926.502
DRILLING :
1. Use a hammer drill (SDS), drill a 1" (25mm) diameter hole at least 5"
(127mm) deep. The drilled hole must be straight and perpendicular to
the surface. Make sure the hole is of uniform diameter and free of peaks and
valleys on the inner wall. See diagram below.
2. Blow hole clean with compressed air.
3. Refer to the diagram below for hole location and requirements.
4. Always inspect the hole carefully when reusing a previously drilled hole.
Hole to Edge:
Us er Ins tru ct ion s - Engl is h
LOADING CONDITIONS DIAGRAM
LOAD
ACCEPTABLE
Drill 1"Ø
(2.54cm)
Section View:
LOAD
ACCEPTABLE
10"
(25.4cm)
5" min
depth
(12.7cm)
1"min
(2.54cm)
20
LOAD
IMPROPER
6"min
(15.24cm)

Hide quick links: