Download Print this page

Installation Instructions; Maintenance; Flow Diagram - Hansgrohe Axor Starck Series Instructions For Use/Assembly Instructions

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal
pressures.
Do not allow the streams of the shower touch
sensitive body parts (such as your eyes). An
adequate distance must be kept between the shower
and you.
The product may not be used as a holding handle. A
separate handle must be installed.

Installation Instructions

• The fitting must be installed, flushed and tested after
the valid norms. Prior to installation, inspect the
product for transport damages.
• After it has been installed, no transport or surface
damage will be honoured.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Anti-pollution function
The product is exclusively designed for drinking water!
Symbol description
Safety Function (see enclosed
brochure.)
The desired maximum temperature for
example max. 42º C can be pre-set thanks
to the safety function.
4
English
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4min
Assembly see page 32
Adjustment (see page 35)
After the installation, the output temperature
of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.

Maintenance

To guarantee the smooth running of the
thermostat, it is necessary from time to time
to turn the thermostat from total hot to total
cold.
Maintenance non return valve
(see page 36)
The non return valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
Maintenance Secuflex hose (see
page 36)
Repeat cleaning when pull out becomes
difficult.
Do not use silicone containing acetic acid!
Dimensions (see page 31)

Flow diagram

(see page 31)
Hand shower
Bath Spout
Spare parts (see page 40)
Operation (see page 38)
Test certificate (see page 31)

Advertisement

loading