9.3

TM15 Terminal Module

Properties
Terminal Module TM15 provides drive-related digital inputs and outputs with short signal
delay times. TM15 is connected by means of DRIVE-CLiQ.
Each of the 24 isolated DI/DOs can be parameterized channel-by-channel as a digital input
(DI) or digital output (DO).
Additional references
You can find additional information on the TM15 in the SINAMICS S120 manual titled
"control units and Additional System Components".
CAUTION
The cooling clearances of 50 mm above and below the component must be observed.
9.4

DRIVE-CLiQ Hub Module DMC20

Properties
The DRIVE-CLiQ DMC20 Hub Module is used to implement point-to-point distribution of a
DRIVE-CLiQ line. With the DMC20, an axis grouping can be expanded with 4 DRIVE-CLiQ
sockets for additional subgroups.
The module is especially suitable for applications which require DRIVE-CLiQ nodes to be
removed in groups, without interrupting the DRIVE-CLiQ line and therefore the data
exchange.
CAUTION
The cooling clearances of 50 mm above and below the component must be observed.
Additional references
You can find further information on the DMC20 in the SINAMICS S120 manual titled "Control
Units and Additional System Components".