Input And Output Signals Of Connectors; 18 (E) - Sony HKSP-R80 Installation Manual

Routing switcher controller
Hide thumbs Also See for HKSP-R80:
Table of Contents

Advertisement

7. Input and Output Signals of
Connectors
The input and output signals of the connectors at the rear
panel are as follows.
REMOTE2 A/B : RS-422A (D-sub 9-pin, Female)
5
9
_ EXT VIEW _
Pin No.
Signal name
Input/Output
_
1
FG
2
TX (_)
O
3
RX (+)
I
4
GND
_
5
_
_
6
GND
_
7
TX (+)
O
8
RX (_)
I
_
_
9
The frame ground and the common ground are connected
internally inside the system.
REMOTE3 : RS-232C (D-sub 9-pin, Male)
1
6
_ EXT VIEW _
Pin No.
Signal name
Input/Output
1
DCD
I
2
RX
I
3
TX
O
4
DTR
O
_
5
GND
6
DSR
I
7
RTS
O
8
CTS
I
9
_
_

18 (E)

1
6
Function
Frame ground
Transmitted data (_)
Received data (+)
Common ground
No connection
Common ground
Transmitted data (+)
Received data (_)
No connection
5
9
Function
Date carrier detect
Received data
Transmitted data
Data terminal ready
Signal ground
Date set ready
Request to send
Clear to send
No connection
DATA :
10BASE-T/100BASE-TX (RJ-45 8-pin Modular jack)
1
_ EXT VIEW _
Pin No.
Signal name Input/Output
1
TDB
O
2
TDA
O
3
RDB
I
4
BI_D3+
_
5
BI_D3_
_
6
RDA
I
7
BI_D4+
_
_
8
BI_D4_
*1 : This signal line is not used in this system. It is connected to the
termination circuit inside the system.
8
Function
Transmitted data B
Transmitted data A
Received data B
(*1)
(*1)
Received data A
(*1)
(*1)
HKSP-R80

Hide quick links:

Advertisement

Table of Contents