6.3. Communication Configuration

6.3.1. COM Port For OSW
• Com Port connects or disconnects the communication between PC and MLCD.
• Connect MLCD to PC Com Port via RS-232C cable.
• Go to "OSW Menu → CONNECTION → CONNECT" and select the comport you want to
connect.
• In order to disconnect the communication, click "DISCONNECT"..
• When you use USB-to-RS-232C converters, you need to set Com Port again,
because OSW uses one of Com Port no. 1 to 30.
※Available Com Port on the PC is automatically recognized and displayed.
6.3.2. LAN Port For OSW
• LAN Port connects or disconnects the communication between PC and MLCD.
• Connect MLCD to PC LAN Port via LAN cable.
• Go to "OSW Menu → CONNECTION → CONNECT" and select the LAN port you want to
connect.
• In order to disconnect the communication, click "DISCONNECT"..
※Destination IP address is configured using "SOCKET SETUP" menu.
※Destination IP address is IP address of the MLCD you want to connect.
- 42 -
6.3.3.
Socket Setup
1. Execute the OSW.
2. Select "OSW Menu → CONNECTION → SOCKET SETUP".
3. Type in IP Address of MLCD.
4. Click "PING TEST" to check status of communication.
5. Close the Communication setup window
Socket Setup Menu Description
Edit Box : Set the IP address.
Port Number : Fixed as 9761.
* Caution: You cannot change the port number.
Ping Test: Test the IP address.
SOCKET SETUP