Electrical Connections - Viking 5 Series Installation Use & Care Instructions

Outdoor gas grills
Table of Contents

Advertisement

ELECTRICAL CONNECTIONS

WARNING: ELECTRICAL GROUNDING
• Product installation must meet local electric codes or, in the absence of local codes, the latest edition of the
National Electrical Code ANSI/NFPA No. 70 or the Canadian Electrical Code CGA 1.6b2005.
• Use only a Ground Fault Interrupter (GFI) protected circuit with this outdoor cooking gas appliance.
• IMPORTANT: When connecting your rotisserie motor, fi rst connect the motor to the grill and then plug the grill
into the outlet.
• This grill is equipped with a three prong (grounding) electric plug for your protection against shock hazard and
must be plugged directly into a properly grounded three prong outlet. Never cut or remove the grounding
prong from this plug.
• Use only extension cords with a 3 prong grounding plug, rated for the power of the equipment, and approved
for outdoor use with a "W-A" marking.
• To protect against electric shock, do not immerse any part of the power cord, an extension cord or any plugs in
water or other liquid.
• Unplug the product from the outlet when not in use and before cleaning. Allow it to cool before putting on or
taking off parts.
• Do not let the cord hang over the edge of a table or touch hot surfaces.
• Do not use an outdoor cooking gas appliance for purposes other than intended.
• Do not operate any outdoor cooking gas appliance with a damaged cord, plug, or after the appliance
malfunctions or has been damaged in any manner. Contact the manufacturer for repair.
CONNECTION TO AC
Installation requires an outdoor 120VAC 15A GFI (Ground
Fault Interrupter) electrical outlet adjacent to the grill.
The GFI outlet features an internal breaker that reduces
shock hazard. This type of outlet should be installed by a
qualifi ed electrician either inside the island enclosure for
built-in units, or near the location where a free-standing unit
will be used.
For built-in grills, the supplied 12VDC should be installed
below the grill within the cabinet enclosure. Select a
location where the transformer is protected against water,
heat and physical damage.
When installing the transformer to the grill be careful to
prevent the wiring and transformer from contacting any
hot surfaces behind or below the grill. It is recommended
that the transformer be located below the grill in a readily
accessible location. Be sure to provide adequate access to
facilitate service if the transformer or connections should
need future maintenance.
If the electrical system fails to operate, a connection may
have come loose in shipping or the GFI may have tripped,
requiring a reset. See the Troubleshooting section for more
details.
INSTALLATION / USE & CARE
|
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents