RAM diagnostics failed
1719 - 57
Fixed disk drive controller
to drive test failed
1719 - 58
Failed to write sector buffer
1719 - 59
Failed to read sector buffer
1719 - 60
Failed to compare sector buffer
------------------------------------------------------------------------------
Error
Code
Description
------------------------------------------------------------------------------
1719 - 61
Failed uncorrectable
ECC error
1719 - 62
Failed correctable ECC error
1719 - 63
Failed soft error rate
1719 - 65
Exceeded maximum bad sector
per track
1719 - 66
Failed initial drive parameter
1719 - 67
Failed to write long
1719 - 68
Failed to read long
1719 - 69
Failed to read drive size from
controller
1719 - 70
Failed translate mode
1719 - 71
Failed nontranslated mode
1719 - 72
Bad track limit exceeded
1719 - 73
Previously exceeded bad track limit
1719 - 74
Failed sleep mode
1719 - 75
Failed idle mode
1719 - 76
Failed standby mode
1719 - 77
Failed to change mode
1719 - 78
Exceeded spinup time limit
==============================================================================
Table 3-10.
Tape Drive Test Error Codes
==============================================================================
Recommended Action
The following steps apply to error
codes 1700 - xx through 1799 - xx:
1.
Replace the fixed disk drive
signal and power cables and
retest.
2.
Replace the fixed disk drive and
retest.
3.
Replace the system board and
retest.