Table 3-7.
Serial Test Error Codes
==============================================================================
Error
Code
Description
------------------------------------------------------------------------------
1101 - 01
Serial Port Test:
DLAB bit failure
1101 - 02
Serial Port Test; line
input or UART fault
1101 - 03
Serial Port Test; address
line fault
1101 - 04
Serial Port Test; data
line fault
1101 - 05
Serial Port Test; UART
control signal failure
1101 - 06
Serial Port Test; UART
THRE bit failure
1101 - 07
Serial Port Test; UART
DATA READY bit failure
1101 - 08
Serial Port Test; UART
TX/RX buffer failure
1101 - 09
Serial Port Test; INTERRUPT
circuit failure
------------------------------------------------------------------------------
Error
Code
Description
------------------------------------------------------------------------------
1101 - 10
Serial Port Test; COM1 set
to invalid interrupt
1101 - 11
Serial Port Test; COM2 set
to invalid interrupt
1101 - 12
Serial Port Test; DRIVER/
RECEIVER control signal
failure
1101 - 13
Serial Port Test; UART
control signal interrupt
failure
1101 - 14
Serial Port Test; DRIVER/
RECEIVER data failure
1109 - 01
Clock register initialization
failure
1109 - 02
Clock register rollover
failure
1109 - 03
Clock reset failure
Recommended Action
UART
The following steps apply to error
codes 1101 - xx through 1109 - xx:
1.
Replace the serial interface
board and retest.
2.
Replace the system board and
retest.