• WHISKS
The whisks can be cleaned either by hand or in a
dishwasher.
To ensure effective cleaning, always remove the
whisk ejector.
• BLADE
Over time the blades will become worn and will
need to be replaced. The washer and seals should
also be replaced at this time. A blade service kit is
available.
• TUBE SEAL
In order to maintain a watertight seal between the
tube and bell, inspect the seal for wear and replace
it if necessary.
• SEAL RING
The seal ring can be lubricated using a suitable
food grade grease. In order to maintain a
watertight seal, check the seal ring for wear and
replace it if necessary.
• WHISKS
The performance of the whisks depends on the
condition of the wires. The metal wires may become
worn over time. In order to ensure optimum
performance, they will need to be replaced. Do not
use a defective or damaged whisk!
10
• THE POWER MIXER DOES NOT START.
- Did you follow the previous operating instructions?
See section-Operating The Power Mixer.
- Is the machine too hot? Allow the power mixer to
MAINTENANCE
cool. Then retry.
- Pull the plug and try another outlet.
- Check outlet for current (breaker or fuse).
- Call local Robot Coupe authorized service agency.
• THE POWER MIXER STOPS DURING (WHILE)
PROCESSING.
See the section on Operating the power Mixer. The
first paragraph describes the overload protection. It
may be necessary to allow the machine to cool for
up to 30 minutes before restarting.
If you cannot locate the cause of the problem
- Release the control button (CB).
- Unplug the power mixer.
- Are the blades free to rotate in the bell?
- Is the drive shaft free to rotate? To check this,
unplug the power mixer, remove the bell and test
the rotation of the end of the drive shaft manually.
Check the condition of the plug and the power cord.
• THE POWER MIXER STARTS TO SMELL HOT
OR SMOKE.
Turn the power mixer off and unplug it. Call your
local authorized service agency.
TROUBLE SHOOTING
W A R N I N G
• THE BLADES ARE SHARP! It is recommended
that cutting gloves be worn when handling
the blades. Handle and store the blades
with safety in mind.
• Never try to defeat the safety mechanisms!
• Never put anything (utensils etc.) but food
material near the blades on the power
mixer!
• Never overload the power mixer!
• Never turn the power mixer on unless the
bell is completely immersed in the product.
• Always unplug the power mixer before
doing any cleaning or maintenance!
See warranty first then;
Should your unit require service, check with your
distributor to see where local service is available.
If not or if you wish your unit to be serviced at the
factory, call for return instructions and ship the unit
prepaid to our factory address.
PH : 1-800-824-1646
Robot-Coupe USA, Inc
Service Department Repair
264 South Perkins Street
Ridgeland, MS 39157
For service in Canada contact the Robot-Coupe
USA factory for repair instructions.
SERVICE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cmp 250 combiCmp 300 combi

Table of Contents