Our guarantee becomes null and void if the unit is used, set up or maintained improperly, or if modifications are made to the supplied unit without our prior consent. Subject to alterations. Portable air dehumidifier REMKO ETF 220 Contents Contents Page...
The ambient air is heated to absorb moisture and ex- pelled to the outside. However, the total generated energy is lost with the expelled humid air. The Use of REMKO Air Dehumidifiers 2. By dehumidifying: The humid air in the closed room is continuously de- ◊...
Page 5
◊ The air augmented with water vapour continuously When materials or rooms are to be dried, the heat en- circulates through the REMKO air dehumidifier. It is ergy flows in a cycle, i.e. it is consumed during evapora- dehumidified and leaves the unit in a slightly warm...
Safety Instructions Extensive tests have been conducted on the material, A fully-automatic control, the condensation collector with integrated overflow prevention mechanism and the con- functionality and quality of this unit before it was shipped. nection adapter for direct drainage of condensation en- sure that the unit run smoothly in smooth operation.
◊ If the unit is in operation in a dusty environment, the Depending on the air temperature and the relative hu- midity, the condensed water drips out steadily or only appropriate service and maintenance measures are during periodic defrosting phases into the collection to be undertaken in accordance with the specific conditions.
Operation Initial Operation Prior to initial operation or to meet local requirements, Control panel the air intake and outlet openings must be inspected for The display and the buttons for operating the unit are lo- foreign bodies and the air intake filter for dirt. cated on the control panel.
Page 9
Instructions for unit operation Automatic defrost ◊ After being switched on, the unit functions fully auto- The humidity contained in the ambient air condenses matically until it is switched off by a control mecha- when cooled and covers the evaporator fins with frost or nism activated by the float when the condensation ice depending on the air temperature and the relative humidity.
Timer mode Prior to longer periods of non-operation The “Timer” button (see page 8) is used to activate 1. Unplug the power cord. operation of the unit at a programmed time. The unit 2. Empty the condensation collector and dry it with a switches on or off after the preset time has elapsed.
Maintenance and Service Troubleshooting Regular maintenance and observance of some basic The unit was tested repeatedly during production to en- principles are required to ensure a long service life and sure that it is working properly. to keep the unit functioning properly. However, should problems occur, refer to the following However, the unit should be inspected at least once a list.
% r. h. 40-100 tomer must completely fill out the "guarantee certificate" Dehumidification capacity max. l/day enclosed with all units and send it back to REMKO GmbH & Co. KG at 30 °C / 80 % r.h. l/day 20.6 The units are repeatedly tested at the production site to Air capacity, min./max.