NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
4
5 4
5
2
5
Set the desired pulse delay.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
4
5 4
5 4
5
2
0
0
Note
Programming Example
3-10
Generating Signals
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
NNNNNNNNNNN
NNNNNNNNNNN
Presets the signal generator.
Sets pulse source to internal.
Sets pulse trigger source to immediate (non-
triggered).
Turns pulse modulation on.
Enables internal leveling.
Sets the carrier frequency to 3.085 GHz.
Sets the output amplitude to 26 dBm.
Turns average power inhibit on or o .
Sets the pulse repetition interval to 100 ms.
Sets the pulse width to 25 ms.
Sets the pulse delay to 200  s.
Turns the RF output on.