Eaton 220 Service Manual page 21

Hide thumbs Also See for 220:
Table of Contents

Advertisement

Pump repair
Cont.
9. Remove housing O-rings
11. Swashplate adjustment locator with the hold down
tool in place, tighten the adjustment screw so the control
piston spring is compressed.
Note: This step is designed to force the swashplate to a neutral position to
enable easy removal of the rotating group, and to retain the swashplate.
13. Remove rotating group
15. Remove swashplate locator
10. Install Swashplate retainer install the swash plate
hold down tool and tighten the cap screw. This will
prevent the swash plate from moving.
12. Install shaft retainer tool and tighten the set screw
while being careful not to damage shaft.
14. Remove shaft remove shaft retainer tool and lift out
shaft. Use caution when moving shaft through shaft seal.
16. Remove swashplate retainer
EATON 220 Piston Pump Service Manual E-SRSR-RR002-E August 2019