ICP iMAT 32VBI-ELV Instructions For Installation And Operation Manual
ICP iMAT 32VBI-ELV Instructions For Installation And Operation Manual

ICP iMAT 32VBI-ELV Instructions For Installation And Operation Manual

Condensate drain.

Advertisement

EN-US - english US
Instructions for installation and operation
Condensate drain
¡MAT 32VBI-ELV

Advertisement

Table of Contents
loading

Summary of Contents for ICP iMAT 32VBI-ELV

  • Page 1 EN-US - english US Instructions for installation and operation Condensate drain ¡MAT 32VBI-ELV...
  • Page 2 Dear customer, Thank you for deciding in favor of the iMAT 32VBI-ELV condensate drain. Please read the installation and operating instructions carefully before mounting and starting up the iMAT 32VBI-ELV, and follow our directions. Perfect functioning of the iMAT 32VBI-ELV, and thus reliable condensate discharge, can only be guaranteed when the provisions and notes stipulated here are strictly adhered to.
  • Page 3: Table Of Contents

    Safety instructions ..........................4 Proper use..............................6 Exclusion from the scope of application....................6 Technical data ............................7 Electrical data............................8 Dimension drawing..........................9 Function..............................10 Installation ............................13 Electrical installation..........................16 Control and maintenance ........................19 Troubleshooting and fault elimination ....................23 Elements and components........................24 Recommended spare parts........................24 iMAT 32VBI-ELV...
  • Page 4: Pictograms And Symbols

    In addition to these operating instructions, local or national regulations must be complied with, if necessary. Make sure that the iMAT 32VBI-ELV is operated only within the permissible limit values indicated on the type plate. Any deviation involves a risk for persons and materials, and may result in malfunction and service failures.
  • Page 5 Regarding the inlet screw joints, excessive tightening forces must be avoided. This applies in particular to conical screw joints. • The iMAT 32VBI-ELV will only function when voltage is applied. • Do not use the test button for permanent drainage.
  • Page 6: Proper Use

    Pos : 23 /Beko T ec hnis che D okumentati on/Besti mmungsgemäß e Ver wendung/BEKOM AT/Aus schl uß Anwendung BM nic ht für fros tgefähr dete Bereic he (Zusatz) @ 0\mod_1216106439206_15098.doc x @ 15249 @ @ 1 • The iMAT 32VBI-ELV is not heatable and, therefore, not suitable for the use in areas where frost is likely to occur.
  • Page 7: Technical Data

    This product has been tested to the requirements of CAN/CSA-C22.2 No. 61010-1-12, third edition, includ- ing a later version of the same standard incorporating the same level of testing requirements. Pos : 28 /---- Seitenumbr uch ---- @ 0\mod_1157028099015_0.doc x @ 15320 @ @ 1 iMAT 32VBI-ELV...
  • Page 8: Electrical Data

    VDC = V direct current The switching of loads means that the properties of the contact are no longer suitable for the switching of low signals. Pos : 31 /---- Seitenumbr uch ---- @ 0\mod_1157028099015_0.doc x @ 15320 @ @ 1 iMAT 32VBI-ELV...
  • Page 9: Dimension Drawing

    Pos : 33 /Beko T ec hnis che D okumentati on/Tec hnische D aten/M assz eichnung @ 0\mod_1184569815280_15098.doc x @ 15135 @ @ 1 Pos : 34 /---- Seitenumbr uch ---- @ 0\mod_1157028099015_0.doc x @ 15320 @ @ 1 iMAT 32VBI-ELV...
  • Page 10: Function

    Pos : 36 /Beko T ec hnis che D okumentati on/Funkti on/BEKOMAT/BM Vario-F unktion @ 0\mod_1185779978265_15098.doc x @ 15161 @ @ 1 Via the inlet line (1), the condensate flows into the iMAT 32VBI-ELV and accumulates in the housing (2). A capacitive functioning sensor (3) continuously registers the filling level.
  • Page 11 Function At the iMAT 32VBI-ELV, two LEDs indicate the individual operating states. When applying supply voltage, the iMAT 32VBI-ELV carries out a self-test. Both LEDs are lit for approximately 1 second, subsequently, the device changes over to the "ready- to-operate" state.
  • Page 12 Function The iMAT 32VBI-ELV releases a maintenance message for a service that is to be carried out. Depending on the operating mode, a visual maintenance message (service) is activated which signalizes the replacement of the service unit. The maintenance message is indicated by the flashing supply voltage-LED "Power".
  • Page 13: Installation

    (see "Proper use" section) • Exact compliance with the installation- and operation instructions in this manual • Regular maintenance and control of the iMAT in accordance with the instructions in this operating manual iMAT 32VBI-ELV...
  • Page 14 Install manifold (6) ¾" with a slope of 1%. • Introduce the discharge pipe (5) from the top into the manifold (6). • Prior to the start-up, always carry out a leak test and verify the correct engagement of the control unit. iMAT 32VBI-ELV...
  • Page 15 If drainage is to be carried out directly from the pipe, deflection of the air flow will be useful. No venting line! Do not install a venting line for a iMAT 32VBI-ELV! Installations, where a venting line is normally required, are impossible in this case. Another suitable iMAT must be used.
  • Page 16: Electrical Installation

    10.Install the cables as shown (see also terminal assignment in the following text). 11.Tighten the threaded cable connection (3) with a slightly sealing effect. 12.Put on the upper part of the cover (2) and tighten the screws (1) fingertight. iMAT 32VBI-ELV...
  • Page 17 Terminal assignment supply voltage (operating voltage) Power supply • X 1.1 L/+ • X 1.2 N/- L = Outer conductor N = Neutral conductor Terminal assignment low voltage (operating voltage) Power supply • X 1.1 L/+ • X 1.2 N/- iMAT 32VBI-ELV...
  • Page 18 Pos : 54 /Beko T ec hnis che D okumentati on/Installati on/BEKOMAT /E- Schema @ 0\mod_1233758178163_15098.doc x @ 15305 @ @ 1 Electric diagram Pos : 55 /---- Seitenumbr uch ---- @ 0\mod_1157028099015_0.doc x @ 15320 @ @ 1 iMAT 32VBI-ELV...
  • Page 19: Control And Maintenance

    Exact compliance with the installation- and operation instructions in this manual • Regular maintenance and control of the iMAT in accordance with the instructions in this operating manual Pos : 63 /---- Seitenumbr uch ---- @ 0\mod_1157028099015_0.doc x @ 15320 @ @ 1 iMAT 32VBI-ELV...
  • Page 20 1. Prior to the replacement of the service unit, a reset needs to be carried out. The control unit is released by actuating the arresting hook. When removed, the TEST button below the LED must be pressed and held for at least five seconds. iMAT 32VBI-ELV...
  • Page 21 Control and maintenance 2. Remove the control unit (1) by pressing the arresting hook (2). 3. Unfasten the iMAT 32VBI-ELV from the outlet (3). 4. Detach the service unit (5) from the tubing at the inlet by removing the union nut.
  • Page 22 • Leak test of the screwed connector • Check of the electrical connections • Check of the correct engagement of the control unit Pos : 66 /---- Seitenumbr uch ---- @ 0\mod_1157028099015_0.doc x @ 15320 @ @ 1 iMAT 32VBI-ELV...
  • Page 23: Troubleshooting And Fault Elimination

    Service unit extremely dirty Condensate discharge only when the test button is pressed Service unit defective or dirty Replace the service unit Device blows off continuously Pos : 69 /---- Seitenumbr uch ---- @ 0\mod_1157028099015_0.doc x @ 15320 @ @ 1 iMAT 32VBI-ELV...
  • Page 24: Elements And Components

    Pos : 76 /Beko T ec hnis che D okumentati on/Globale Texte/Hinweis Ü bers etzg. d. Orig.anl eitg. @ 1\mod_1260433478358_15098.doc x @ 17131 @ @ 1 Pos : 77 /Beko T ec hnis che D okumentati on/Globale Texte/Vorbehalts klaus el @ 0\mod_1213704033153_15098.doc x @ 15236 @ @ 1 === Ende der Liste für T extmar ke Inhalt === iMAT 32VBI-ELV...
  • Page 25 Filling level 10 Trouble sources 11 Function 10 Troubleshooting 23 Hose connector 24 Upper part of the cover 24 Installation 13 Venting line 15 Installation and operating instructions 4 Installations- und Betriebsanleitung 4 Water pocket 15 Instructions, safety instructions 4 iMAT 32VBI-ELV...
  • Page 26 32VBI-ELV...
  • Page 27 32VBI-ELV...
  • Page 28 Independent Compressor Partners, LLC P.O. Box 206 Jeffersonville, IN 47131 www. compressorpartners.com Translation of the original manual/instructions. Original instructions are in German Subject to technical modifications without notice / errors accepted. ICP_iMAT32_V_BI_ELV_manual_en_us_2014_12. Printed in Germany iMAT 32VBI-ELV...