INSTALLATION INSTRUCTIONS
IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR
SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

GENERAL INSTRUCTIONS:

PREPARING TO INSTALL
CONSULT A LOCAL LICENSED ELECTRICIAN OR ELECTRICAL CONTRACTOR PRIOR TO INSTALLATION.
1.
REVIEW WARNINGS FOUND IN THIS DOCUMENT PRIOR TO STARTING WORK.
2.
INSPECT PACKAGE(S) FOR SIGNS OF DAMAGE. NOTIFY CARRIER IMMEDIATELY IF FIXTURE PACKAGING IS DAMAGED.
3.
UNPACK THE FIXTURES FROM PACKAGING. RECYCLE AND PROPERLY DISPOSE OF PACKAGING.
4.
INSPECT FIXTURES. IF THERE IS ANY FIXTURE DAMAGE OBSERVED, TAKE PHOTOGRAPHS AND IMMEDIATELY CONTACT LIGHTING.TECH@FLEX.COM.
5.
TURN OFF ELECTRICITY AT THE MAIN CIRCUIT BREAKER, PANELBOARD, FUSE BOX OR DISCONNECT.
6.
DO NOT ATTEMPT TO INSTALL FIXTURE WITH THE POWER ON.
ENSURE FIXTURE IS PROPERLY RATED FOR RESPECTIVE LOCATION.
7.
MAKE SURE THE MOUNTING SURFACE IS CAPABLE OF SUPPORTING WEIGHT OF FIXTURE.
8.
MAX AMBIENT REDUCED 5°C WHEN MOUNTED NEAR CEILING.
9.
ENSURE PROPER AIRFLOW AROUND FIXTURE.
10.
REMOVING LED LIGHT COVER (FXT ONLY):
1.
GENTLY SQUEEZE THE LINEAR HOUSING BELOW THE SIDE TABS AND REMOVE THE LED LIGHT COVER TO ACCESS FIXTURE WIRING.
2.
IF APPLICABLE, REMOVE DRIVER GREEN/YELLOW STRIPE GROUND WIRE FROM GROUNDING WAGO CONNECTOR.
3.
SET LED LIGHT COVER ASIDE UNTIL READY TO MAKE ELECTRICAL CONNECTIONS. REFER TO "MAKING ELECTRICAL CONNECTIONS" FOR WIRING INFORMATION.
4.
DETERMINE HOW FIXTURE WILL BE MOUNTED, AND GO TO APPROPRIATE INSTRUCTION.
JOINING FIXTURE SECTIONS (FXT ONLY):
1.
IDENTIFY SECTIONS –
8' SECTIONS ARE MARKED "8A" AND "8B"
12' SECTION ARE SECTIONS MARKED "12A", "12B" AND "12C".
SECTION "8A (12A)" HAS THE DRIVER.
8 FT SECTION COMES WITH 3 END CAPS: (1 EA) INSTALLED ON "8A" SECTION, (1 EA) INSTALLED ON "8B" SECTION, (1 EA) ENDCAP WRAPPED UP AND
TUCKED INSIDE HOUSING OF SECTION "8B" AND (1 EA) JOINER PLATE.
12 FT SECTION COMES WITH 4 END CAPS: (1 EA) INSTALLED ON "12A" SECTION, (1 EA) INSTALLED ON "12C" SECTION, (2 EA) ENDCAPS WRAPPED
UP AND TUCKED INSIDE HOUSING OF SECTION "12B" AND (2 EA) JOINER PLATES.
FLEXLIGHTINGSOLUTIONS.COM
LIGHTING.TECH@FLEX.COM
LINEAR SERIES
913-851-3000
11-13-17