Replacing An Enclosure Management Module; Identifying The Failed Enclosure Management Module - Dell Storage Center SC200 Service Manual

Hide thumbs Also See for Storage Center SC200:
Table of Contents

Advertisement

8 Replace the front bezel as described on
9 In the Storage Center System Manager, make sure that the replacement hard drive is
recognized and shown as up and running. If the Storage Center System Manager
informs you that there are unassigned disks, see the Storage Center System Manager
Administrator's Guide for instructions on managing unassigned disks.
10 Perform a Phone Home and contact Dell Technical Support Services as described on
page

Replacing an Enclosure Management Module

The SC200 and SC220 enclosures support redundant hot-swappable enclosure
management modules (EMMs).
EMMs provide the following data path and enclosure management functions for the
enclosure:
Monitoring and controlling enclosure environment elements such as temperature, fan,
power supplies, and enclosure LEDs
Controlling access to hard drives
Communicating enclosure attributes and states to the enclosure

Identifying the Failed Enclosure Management Module

To determine which EMM failed, use the Storage Center System Manager.
1 In the System Tree, expand the Enclosures entry.
2 Expand the failed enclosure entry (indicated with a red dot).
3 Click IO Modules. The status of each EMM is displayed.
4 To see the location of the failed EMM, expand the IO Modules entry, and click on the
failed EMM entry to display a rear view of the enclosure.
Dell Compellent
Note: Allow several seconds for the enclosure to recognize the hard drive and
determine its status. When functioning properly, the hard drive's status LED turns
green. In addition, the hard drive indicator turns green in the Storage Center
System Manager.
24.

Replacing an Enclosure Management Module

page
9.
17