Installation and Configuration WARNING: Before performing the following procedure, review the safety instructions that came with all Storage Center components. Unpacking the System NOTE: Unpacking, installing, and deploying your Storage Center may be done only by a certified service technician. Before you begin, make sure the site where you intend to set up and use the Storage Center has the following: •...
Page 4
Always load the rack from the bottom up for weight stability. • You can allow room for expansion if you have fewer than the • maximum number of enclosures. 8 Unwrap and insert each drive into the enclosure one at a time. Protect the drive from static discharge.
Page 5
Connecting the Power Cables 1 Ensure that the power switch is in the OFF position before connecting the power cables. 2 Connect the enclosure power cables to the rack power. Securing the Power Cables 1 Bend the power cables as shown in the illustration and secure the cables firmly to the bracket using the strap provided.
Page 6
2 Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU). Location of Power Button NOTE: Do not power up the enclosure until all Storage Center components are racked and cabled.
Other Information You May Need WARNING: See the safety and regulatory information that shipped with your Storage Center components. Warranty information may be included within this document or as a separate document. • The rack documentation included with your rack solution describes how to install your system into a rack.
The following information is provided on the device described in this document in compliance with the requirements of the official Mexican standards (NOM): Importer: Dell Inc. de México, S.A. de C.V Paseo de la Reforma 2620-11 ° Piso Col. Lomas Atlas 11950 México, D.F.
Page 9
Management RAID management using Storage Center System Manager version 6.2 or later Back-Plane Board Connectors • SC200: 12 SAS hard-drive connectors • SC220: 24 SAS hard-drive connectors • Two power supply/cooling fan module connectors • Two sets of EMM connectors •...
Page 10
10 ms or less Available Hard Drive Power (Per Slot) Supported hard drive power SC200: Up to 1.16 A at +5 V, consumption (continuous) Up to 1.6 A at +12 V SC220: Up to 1.2 A at +5 V, Up to 0.5 A at +12 V...
Page 11
Physical (continued) Weight (maximum configuration) SC200: 29.2 kg (64 lb) SC220: 24 kg (53 lb) Weight (empty) SC200: 8.84 kg (19.5 lb) SC220: 8.61 kg (19 lb) Environmental NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.
Page 12
Environmental (continued) Storage • Half-sine shock 71G +/- 5% with a pulse duration of 2ms +/- 10% (all sides) • Square wave shock 27G with a velocity change of 235 in/sec (all sides) Altitude Operating –16 to 3048 m (–50 to 10,000 ft) NOTE: For altitudes above 2950 feet, the maximum operating temperature is...