Disassembly Instructions
VCZ
Identification of plastic parts and electronics parts
FLY637_B
Non contractual document. Aereco reserve the right to make changes to the construction and to the technical data of the fan.
ENGLISH

Advertisement

Table of Contents
loading

Summary of Contents for Aereco VCZ Series

  • Page 1 Disassembly Instructions ENGLISH Identification of plastic parts and electronics parts FLY637_B Non contractual document. Aereco reserve the right to make changes to the construction and to the technical data of the fan.
  • Page 2: Table Of Contents

    4.6. Disassembly of the fan (internal fan housing) ................20 4.7. Component Parts: Fan ........................25 Legal notice ........................... 26 Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
  • Page 3: Introduction

    Secure against unintentional restart. Do not open the housing before the complete stop of the fan impeller. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH...
  • Page 4: Overview

    Torx T20 Combination Needle nose Side cutting pliers Wire cutter pliers pliers Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str. 28 - 09387 JAHNSDORF FRANCE GERMANY Tel.
  • Page 5: Dissassembly Manipulations

    Allen Key AF 5 Unscrew the hexagon socket head cap screws M6 x 16 (depending on model) using an Allen key AF 5. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
  • Page 6: Disassembly Of The Pressure Control Unit

    1.0 x 5.5 Unscrew the cover screw connections (4x) using a screwdriver 1.0 x 5.5. Remove the cover from the casing. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
  • Page 7 AF 27 Needle nose pliers Universal Loosen the head of the cable gland (3x) using a wrench AF 27. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
  • Page 8 Remove all cables by pulling them through the cable glands. Pull off all pneumatic hoses from the hose nipples. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
  • Page 9 Removing the pressure control unit from the fan casing Screwdriver TX 20 Remove the self-tapping screws ST 4.2 x 13 (4x) using a screwdriver TX 20. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
  • Page 10 Screwdriver PZ 2 Remove the fixing screws M6 x 10 (4x) of the circuit board using a screwdriver PZ 2. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
  • Page 11: Component Parts: Pressure Control Unit

    Circuit board Electronics assembly Accessories Cable glands Polyamide >Seal Neoprene Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str. 28 - 09387 JAHNSDORF FRANCE GERMANY Tel. +33 1 60 06 26 63 – fax +33 1 64 80 47 26 Tel.
  • Page 12: Disassembling The Proximity Switch

    0.6 x 3.5 Remove the case cover by turning the cover screws (4x) alternately using a screwdriver 0.6 x 3.5. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
  • Page 13 AF 22 Needle nose pliers universal Loosen the head of the cable gland using a wrench AF 22. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str. 28 - 09387 JAHNSDORF...
  • Page 14 Press the cable clamp firmly together to loose the clamp. At the same time, pull out the two wires using needle nose pliers. Pull the wiring harness through the cable gland and out of the housing. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
  • Page 15 Loosen the screws of the cable clamps (2x) of the cam switch using a screwdriver PH 0. Pull out the cables. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
  • Page 16 0.6 x 3.5 Remove the fixing screw M3 x 15 of the rotary handle using a screwdriver PH 0. Pull off the handle. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
  • Page 17 The locking rim (yellow) is now loose. Pull off the locking rim from the case cover. To remove the display, lever it out of its anchoring using a screwdriver 0.6 x 3.5. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH...
  • Page 18 Remove the fixing screw (2x) of the socket (clear) using a screwdriver PZ 2. Now the cam switch and the case cover including its screws lie free. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH...
  • Page 19: Component Parts: Proximity Switch

    >Display (white) Polyamide >1 >Locking rim (yellow) Polyamide >Rotary handle (red) Polyamide Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str. 28 - 09387 JAHNSDORF FRANCE GERMANY Tel.
  • Page 20: Disassembly Of The Fan (Internal Fan Housing)

    Where the handle pieces are situated, press the cable clamp firmly together (2x). Simultaneously, undo the cable clamps by pulling them apart (2x). Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
  • Page 21 AF 13 Remove the hexagon bolts M8 x 20 (4x) and their corresponding serrated washers M8 using a wrench AF 13. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
  • Page 22 PZ 2 Remove the cheese-head screws with cross recess M6 x 16 (3x) and their corresponding serrated washers M6 using a screwdriver PZ 2. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
  • Page 23 Remove the cable clamps (2x) from the retaining plate. Therefore, press together the retaining pins using the combination plies. Simultaneously, pull out the cable clamp. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH...
  • Page 24 Position the screwdriver 1.0 x 5.5 beneath the balance weight. Go on sliding the screwdriver underneath the balance weight until it comes loose. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
  • Page 25: Component Parts: Fan

    >Rotary handle (red) Polyamide Accessories Cable glands Polyamide >Seal Neoprene Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str. 28 - 09387 JAHNSDORF FRANCE GERMANY Tel. +33 1 60 06 26 63 – fax +33 1 64 80 47 26 Tel.
  • Page 26: Legal Notice

    All rights reserved. No parts of this guide, either text or image may be reproduced or processed in any form or by any means without the prior explicit written permission of the publisher. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH...