Page 1
Disassembly Instructions ENGLISH Identification of plastic parts and electronics parts FLY637_B Non contractual document. Aereco reserve the right to make changes to the construction and to the technical data of the fan.
4.6. Disassembly of the fan (internal fan housing) ................20 4.7. Component Parts: Fan ........................25 Legal notice ........................... 26 Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
Secure against unintentional restart. Do not open the housing before the complete stop of the fan impeller. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH...
Allen Key AF 5 Unscrew the hexagon socket head cap screws M6 x 16 (depending on model) using an Allen key AF 5. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
1.0 x 5.5 Unscrew the cover screw connections (4x) using a screwdriver 1.0 x 5.5. Remove the cover from the casing. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
Page 7
AF 27 Needle nose pliers Universal Loosen the head of the cable gland (3x) using a wrench AF 27. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
Page 8
Remove all cables by pulling them through the cable glands. Pull off all pneumatic hoses from the hose nipples. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
Page 9
Removing the pressure control unit from the fan casing Screwdriver TX 20 Remove the self-tapping screws ST 4.2 x 13 (4x) using a screwdriver TX 20. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
Page 10
Screwdriver PZ 2 Remove the fixing screws M6 x 10 (4x) of the circuit board using a screwdriver PZ 2. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
0.6 x 3.5 Remove the case cover by turning the cover screws (4x) alternately using a screwdriver 0.6 x 3.5. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
Page 13
AF 22 Needle nose pliers universal Loosen the head of the cable gland using a wrench AF 22. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str. 28 - 09387 JAHNSDORF...
Page 14
Press the cable clamp firmly together to loose the clamp. At the same time, pull out the two wires using needle nose pliers. Pull the wiring harness through the cable gland and out of the housing. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
Page 15
Loosen the screws of the cable clamps (2x) of the cam switch using a screwdriver PH 0. Pull out the cables. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
Page 16
0.6 x 3.5 Remove the fixing screw M3 x 15 of the rotary handle using a screwdriver PH 0. Pull off the handle. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
Page 17
The locking rim (yellow) is now loose. Pull off the locking rim from the case cover. To remove the display, lever it out of its anchoring using a screwdriver 0.6 x 3.5. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH...
Page 18
Remove the fixing screw (2x) of the socket (clear) using a screwdriver PZ 2. Now the cam switch and the case cover including its screws lie free. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH...
Where the handle pieces are situated, press the cable clamp firmly together (2x). Simultaneously, undo the cable clamps by pulling them apart (2x). Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
Page 21
AF 13 Remove the hexagon bolts M8 x 20 (4x) and their corresponding serrated washers M8 using a wrench AF 13. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
Page 22
PZ 2 Remove the cheese-head screws with cross recess M6 x 16 (3x) and their corresponding serrated washers M6 using a screwdriver PZ 2. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
Page 23
Remove the cable clamps (2x) from the retaining plate. Therefore, press together the retaining pins using the combination plies. Simultaneously, pull out the cable clamp. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH...
Page 24
Position the screwdriver 1.0 x 5.5 beneath the balance weight. Go on sliding the screwdriver underneath the balance weight until it comes loose. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH FLY637_B LA VALLEE CEDEX 3 Wilhermsdorfer Str.
All rights reserved. No parts of this guide, either text or image may be reproduced or processed in any form or by any means without the prior explicit written permission of the publisher. Aereco S.A. – 62 rue de Lamirault – Collégien 77615 MARNE ZLT Lüftungs- & Brandschutztechnik GmbH...