GE Current Lumination IS Series Installation Manual page 9

Table of Contents

Advertisement

Available languages

Available languages

Connecting a Unit to AC Circuit #1 or AC Circuit #2
Black and
white wires
PSU
7
Locate the black (line) and white (neutral) wires on the
PSU. Pull the wires out of the box to have good access.
AC Circuit #1 Connections
8A
Connect the black (line) and the white (neutral) wires
of the PSU to the AC lines similarly colored wires using
the push-inwire nuts.
9
To terminate a mechanical run take the end cap from
the starter luminaire or starter kit and clip down onto the
last bridge.
AC Circuit #2
AC Circuit #1
Dimming
AC Circuit #1
AC Circuit #2 Connections
8B
Connect the black (line) of the PSU with the brown (line)
AC wire using the push-in wire nut. Connect the white
(neutral) wire of the PSU with the brown/white (neutral)
ACwire using the push-in wire nut.
10
Replace the PSU cover(s) and secure using the mounting
screws.
Note: When installation is complete, all wiring and
connectors shall be totally enclosed.
9