NI 5114 Getting Started Manual

NI 5114 Getting Started Manual

High-speed digitizers
Table of Contents

Advertisement

Quick Links

GETTING STARTED GUIDE
NI High-Speed Digitizers
This document contains English and Japanese language instructions.
This document explains how to install, configure, and test NI high-speed digitizers and
accessories, and how to begin programming them using the NI-SCOPE instrument driver
software. This document applies to the following digitizers and accessories: NI 5105, NI 5114,
NI 5122, NI 5124, NI 5132, NI 5133, NI 5142, NI 5152, NI 5153, NI 5154, NI 5160, NI 5162,
NI 5185, NI 5186, NI 5620, NI 5621, NI 5622, NI 5900, and NI 5922.
For more information on features and programming, refer to the NI High-Speed Digitizers Help.
For device specifications, refer to the specifications document included with your device. To
access these documents, select Start»All Programs»National Instruments»NI-SCOPE»
Documentation.
(Windows 8)
the window that appears.
For the most current versions of documentation, visit
of NI-SCOPE, visit
Contents
Safety and Electromagnetic Compatibility............................................................................... 2
1. Verifying System Requirements........................................................................................... 3
2. Unpacking............................................................................................................................. 3
3. Verifying the Kit Contents ................................................................................................... 3
Other Required Items........................................................................................................ 4
4. Installing the Software.......................................................................................................... 4
5. Installing the Hardware ........................................................................................................ 5
PXI/PXI Express Modules................................................................................................ 5
NI PXIe-5185/5186 Modules ........................................................................................... 6
NI PXIe-5185/5186 Startup Behavior ...................................................................... 8
PCI Devices ...................................................................................................................... 8
USB Devices..................................................................................................................... 9
USB Cable Strain Relief........................................................................................... 10
Mounting the USB-5132/5133 ......................................................................................... 11
Desktop Use.............................................................................................................. 11
DIN Rail Mounting................................................................................................... 11
Panel Mounting......................................................................................................... 12
May 2013
371133T
Click NI Launcher and select NI-SCOPE»Documentation in
ni.com/downloads
ni.com/manuals
.
. For the latest version

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 5114 and is the answer not in the manual?

Questions and answers

Summary of Contents for NI 5114

  • Page 1: Table Of Contents

    This document applies to the following digitizers and accessories: NI 5105, NI 5114, NI 5122, NI 5124, NI 5132, NI 5133, NI 5142, NI 5152, NI 5153, NI 5154, NI 5160, NI 5162, NI 5185, NI 5186, NI 5620, NI 5621, NI 5622, NI 5900, and NI 5922.
  • Page 2: Safety And Electromagnetic Compatibility

    NI 5185/5186 Front Panels ....................25 Previous NI 5185/5186 Modules ................26 NI 5622 Front Panels ......................27 Appendix B: Front Panels for Traditional NI-DAQ (Legacy) Devices........28 NI 5620/5621 Front Panels ....................28 Appendix C: Accessory Front Panels ..................29 NI 5900 Front Panel......................
  • Page 3: Verifying System Requirements

    Remove the digitizer from the package, remove the packing foam and rubber screw covers (PXI/PXI Express devices only), and inspect the digitizer for loose components or signs of damage. Notify NI if the digitizer appears damaged in any way. Do not install a damaged digitizer into your computer or chassis.
  • Page 4: Other Required Items

    LabVIEW or if you are using a third-party tool, install it now. You must install the ADE before installing the NI-SCOPE instrument driver. Install NI-SCOPE by inserting the NI-SCOPE media into the DVD drive. Click Install Software in the displayed window.
  • Page 5: Installing The Hardware

    PC or chassis before installing the hardware. PXI/PXI Express Modules NI PXI and PXI Express modules are sensitive instruments that should be handled carefully. Do not expose the module to temperatures or humidity beyond the rated maximums. Keep the module free of dust by cleaning with compressed air only. Do not clean the device with any solvents or liquids.
  • Page 6: Ni Pxie-5185/5186 Modules

    NI PXI Express Module NI PXIe-5185/5186 Modules Follow the installation instructions in the PXI/PXI Express Modules section to install the NI PXIe-5185/5186 module in PXI Express slots of the chassis. 6 | ni.com | NI High-Speed Digitizers Getting Started Guide...
  • Page 7 The two PXI Express connectors on the NI 5185/5186 module, shown in Note Figure 3, must be connected to the chassis backplane in two adjacent PXI Express slots. Figure 3. NI PXIe-5185/5186 Connector PXI Express Connectors NI PXIe-5186 Module Figure 4. NI 5185/5186 Installation...
  • Page 8: Ni Pxie-5185/5186 Startup Behavior

    NI PXIe-5185/5186 Startup Behavior The first time you install the NI 5185/5186 in the chassis, the NI-SCOPE driver launches a device recognition wizard. After the wizard completes, the NI 5185/5186 module goes through an initialization procedure that lasts approximately 5 to 10 minutes. You must wait until the initialization procedure completes before using the module.
  • Page 9: Usb Devices

    To install a USB device, connect the USB cable to the PC and the digitizer, as shown in Figure 6. Figure 6. USB Installation Laptop Computer NI USB High-Speed Digitizer USB Cable NI High-Speed Digitizers Getting Started Guide | © National Instruments | 9...
  • Page 10: Usb Cable Strain Relief

    Figure 7. USB Cable Strain Relief Options Groove Method USB Cable Zip Tie Method Zip Tie USB Cable Strain Relief Groove (Large) Zip Tie Bar USB Cable Strain Relief Groove (Small) 10 | ni.com | NI High-Speed Digitizers Getting Started Guide...
  • Page 11: Mounting The Usb-5132/5133

    Mounting the USB-5132/5133 You can use the NI USB-5132/5133 on a desktop or mount it to a standard DIN rail or a panel. Desktop Use The NI USB-5132/5133 has plastic guides on the underside that allow it to be stacked on top of other NI USB-5132/5133 devices.
  • Page 12: Panel Mounting

    Set the USB-513x on the screw by fitting it into the bottom screw notch on the underside of the USB-513x. Screw a #8 or M4 screw through the USB-513x top screw hole into the panel. 12 | ni.com | NI High-Speed Digitizers Getting Started Guide...
  • Page 13: Windows Device Recognition

    On some Windows systems, the Found New Hardware wizard opens with a dialog box for every NI device installed. Install the software automatically (Recommended) is selected by default. Click Next or Yes to install the software for each device.
  • Page 14 Windows 8 (64-bit), Windows 7 (64-bit) and Windows Vista (64-bit) do not Note support Traditional NI-DAQ (Legacy) devices. Refer to the NI-SCOPE Readme to determine which operating system is compatible with your digitizer. Record the device number or device name assigned by MAX. You need this identifier when you program your device.
  • Page 15: Programming The Device

    Microsoft Visual C/C++, and all required include and library files are automatically added to the project. Refer to the Creating an Application with Microsoft Visual C and C++ topic of the NI High-Speed Digitizers Help if you prefer to manually add all required include and library files to the project.
  • Page 16: Ni-Scope Examples

    Examples demonstrate the functionality of the device, serving as programming models and building blocks for your own applications. The NI Example Finder is a utility available for some software applications that organizes examples into categories and allows you to easily browse and search installed examples.
  • Page 17: Appendix A: Front Panels For Smc-Based Devices And Usb Devices

    This appendix describes digitizer front panels and signal connections for SMC-based devices and USB devices: NI 5105, NI 5114, NI 5122, NI 5124, NI 5132, NI 5133, NI 5142, NI 5152, NI 5153, NI 5154, NI 5160, NI 5162, NI 5185, NI 5186, NI 5622, and NI 5922.
  • Page 18: Ni 5114 Front Panels

    NI 5114 Front Panels Figure 12 shows the NI PXI-5114 and NI PCI-5114 front panels. For the AUX connector pinout information, refer to Figure 14. Figure 12. NI 5114 Front Panels...
  • Page 19: Ni 5122/5124/5142/5922 Front Panels

    NI 5122/5124/5142/5922 Front Panels Figure 13 shows the NI PXI-5122/5124/5142/5922 and NI PCI-5122/5124/5142/5922 front panels. The NI PXI-5122 and the NI PXIe-5122 front panels are identical. Figure 13. NI 5122/5124/5142/5922 Front Panels NI High-Speed Digitizers Getting Started Guide | © National Instruments | 19...
  • Page 20 PFI 0, and PFI 1 (with optional cable). For pinout information, refer to Figure 14. Figure 14 shows the pin assignments for the 9-pin DIN connector. Figure 14. 9-Pin DIN Connector Pin Assignments for NI 5114/5122/5124/5142/5922 +5 V (Fused) Reserved...
  • Page 21: Ni 5132/5133 Front Panels

    Analog input connection; digitizes data and CH 1 triggers acquisitions. PFI 1 Standard BNC female connector Multipurpose PFI line for sample clock in, digital trigger in/out, and probe compensation. NI High-Speed Digitizers Getting Started Guide | © National Instruments | 21...
  • Page 22: Ni 5152/5153/5154 Front Panels

    NI 5152/5153/5154 Front Panels Figure 17 shows the NI PXI-5152/5153/5154 and NI PCI-5152/5153/5154 front panels. Figure 17. NI 5152/5153/5154 Front Panels ACCESS ACTIVE CH 0 TRIG TRIG CH 1 PFI 0 PFI 1 PFI0 PFI1 Table 5 describes the signal connections for the NI 5152/5153/5154.
  • Page 23: Ni 5160/5162 Front Panels

    1M : 42 Vpk MAX 1M : 42 Vpk MAX CH 1 CH 1 TRIG TRIG Table 6 describes the signal connections for the NI 5160/5162 (2 CH). Table 6. NI 5160/5162 (2 CH) Front Panel Signal Connections Connector Description Function CH 0, Standard BNC connector Analog input connection;...
  • Page 24: Ni 5160/5162 (4 Ch)

    Table 6. NI 5160/5162 (2 CH) Front Panel Signal Connections (Continued) Connector Description Function PFI 0 Standard SMB jack Digital trigger in/out. PFI 1 Standard SMB jack Digital trigger in/out, probe compensation. NI 5160/5162 (4 CH) Figure 19 shows the NI 5160/5162 (4 CH) front panel.
  • Page 25: Ni 5185/5186 Front Panels

    Table 7 describes the signal connections for the NI 5160/5162 (4 CH). Table 7. NI 5160/5162 (4 CH) Front Panel Signal Connections Connector Description Function CH 0 ... CH 3 Standard BNC connector Analog input connection; digitizes data and triggers acquisitions.
  • Page 26: Previous Ni 5185/5186 Modules

    External analog trigger connection. Previous NI 5185/5186 Modules Early versions of the NI 5185/5186 only support 50 Ω input impedance. If the front panel of your NI 5185/5186 looks different from the front panels shown above, you may have an earlier version of the device.
  • Page 27: Ni 5622 Front Panels

    CLK IN SMA female connector Imports an external reference clock or sample clock to the digitizer. CLK OUT SMA jack connector Exports the digitizer reference clock or sample clock. NI High-Speed Digitizers Getting Started Guide | © National Instruments | 27...
  • Page 28: Appendix B: Front Panels For Traditional Ni-Daq (Legacy) Devices

    REF CLK IN REF CLK IN +16 dBm MAX +20 dBm MAX ±10 VDC MAX ±10 VDC MAX PFI 1 PFI 1 TTL (+5 V MAX) TTL (+5 V MAX) 28 | ni.com | NI High-Speed Digitizers Getting Started Guide...
  • Page 29: Appendix C: Accessory Front Panels

    This appendix describes the front panel and signal connections for the digitizer accessory. NI 5900 Front Panel Figure 23 shows the NI PXI-5900 differential amplifier front panel and the connections to the NI 5922. NI High-Speed Digitizers Getting Started Guide | © National Instruments | 29...
  • Page 30 CH 0 + CH 0 - OUT 0 CH 1 + CH 1 - OUT 1 Table 11 describes the signal connections for the NI 5900. Table 11. NI 5900 Front Panel Signal Connections Connector Description Function CH 0+ Standard BNC female connector...
  • Page 31: Appendix D: Troubleshooting

    MAX, refer to section 6. Configuring and Testing in MAX. If the back panel LED still fails to light, contact NI Technical Support at ni.com/ support NI High-Speed Digitizers Getting Started Guide | © National Instruments | 31...
  • Page 32: Device Does Not Appear In Max

    Press <F5> to refresh the list of installed devices. If the device is still not listed, power off the system, verify that the device is correctly installed, and restart. If the device still does not appear under Devices and Interfaces, contact NI Technical Support at ni.com/support Device Failed the Self-Test The MAX self-test performs a brief test of device resources.
  • Page 33: Setting Up Smc-Based Devices For Synchronization

    In the MAX configuration tree, Right-click NI-DAQmx Devices. Select Create New NI-DAQmx Device»RTSI Cable. Right-click the RTSI cable, then select the device to add to the RTSI cable. NI High-Speed Digitizers Getting Started Guide | © National Instruments | 33...
  • Page 34: Appendix E: Where To Go For Support

    NI Application Engineers. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer’s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety.
  • Page 35 Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for more information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patents Notice at ni.com/patents.
  • Page 36 て説明します。 このドキュメントは、 NI 5105 、 NI 5114 、 NI 5122 、 NI 5124 、 NI 5132 、 NI 5133 、 NI 5142 、 NI 5152 、 NI 5153 、 NI 5154 、 NI 5160 、 NI 5162 、 NI 5185 、 NI 5186 、...
  • Page 37: 安全対策と電磁両⽴性について

    NI 5122/5124/5142/5922 フロントパネル ................21 NI 5132/5133 フロントパネル ......................23 NI 5152/5153/5154 フロントパネル ....................24 NI 5160/5162 フロントパネル ......................25 NI 5160/5162 ( 2 CH ) ........................25 NI 5160/5162 ( 4 CH ) ........................26 NI 5185/5186 フロントパネル ......................27 旧バージョン NI 5185/5186 モジュール ................28 NI 5622 フロントパネル ........................29 付録...
  • Page 38: デバイスをパッケージから取り出す

    NI スペクトル計測ツールキットメディア(特定の SMC 対応デバイスキット – のみ) USB ケーブル( USB デバイスのみ) – NI SignalExpress メディア( USB デバイスのみ) – メモ SMC 対応デバイスは、ナショナルインスツルメンツ SMC ( Synchronization and Memory Core )アーキテクチャに基づいています。 詳細については、 『 NI 高速デジタイザヘルプ』を参照してください。 NI 高速デジタイザ スタートアップガイド | © National Instruments | 3...
  • Page 39: その他必要となるもの

    – ドキュメント デスクトップまたはノートブック PC およびドキュメント ( USB デバイス) – デスクトップコンピュータおよびドキュメント ( PCI デバイス) – メモ PCI デバイスで NI-TClk による同期を⾏う場合は、 RTSI ケーブルを使 用して PCI デバイスを接続する必要があります。 詳細については、 NI 高速 デジタイザヘルプ→プログラミング→リファレンス→ NI-TClk 同期ヘルプ を参照してください。 ソフトウェアをインストールする 注意 ハードウェアは、必ずソフトウェアをインストールした後に取り付 けてください。 ソフトウェアをインストールするには、以下の手順に従ってください。 1. (オプション) LabVIEW やサードパーティから提供されているツールなどのアプ...
  • Page 40: ハードウェアを取り付ける

    PXI Express モジュールは、シャーシ内の PXI Express スロットに取り付けることがで きます。 PXI Express スロットを示す表記については、シャーシのドキュメントを参照 してください。 PXI/PXI Express モジュールを取り付けるには、以下の手順に従ってください。 モジュールを取り付ける前に、 PXI/PXI Express シャーシの電源を切り、プラグを 抜きます。 PXI/PXI Express シャーシにファンの速度設定が複数ある場合には、 HIGH に設定 します。 PXI/PXI Express シャーシを配置する際は、吸排気口が遮蔽されないよう注意しま す。 詳細については、各シャーシのドキュメントを参照してください。 モジュールの着脱用ハンドルがラッチされていない状態(下向き)になっている ことを確認します。 NI 高速デジタイザ スタートアップガイド | © National Instruments | 5...
  • Page 41 モジュールの脱着ハンドル部分を持ちながら、図 1 ( PXI モジュール) 、図 2 ( PXI Express モジュール) 、図 3 ( NI PXIe-5185/5186 モジュール)のようにモ ジュールを使用可能なスロットに差し込みます。 モジュールの底部がシャーシの ガイドに固定されていることを確認します。 モジュールを完全にシャーシに押し込み、脱着ハンドルを引き上げて固定しま す。 モジュールのフロントパネルの上下を取り付けネジで固定します。 両方のネジが 適切に締められていないと、パフォーマンスに影響が出る恐れがあります。 PXI/PXI Express シャーシファンが動作し、通気を妨げるようなほこりや汚れがつ いていないことを確認します。 モジュールを動作する前に、フィラーパネルまたはスロットブロッカー ( で購入可能)を使用して、すべての空のシャーシスロットに取り付け ni.com てください。 10. シャーシの電源ケーブルプラグを差し込み、電源を投入します。 図 モジュールの取り付け 1. PXI PXI シャーシ...
  • Page 42: Ni Pxie-5185/5186 モジュール

    NI PXIe-5185/5186 モジュール 「 PXI/PXI Express モジュール」セクションの取り付け手順に従って、 NI PXIe-5185/5186 モジュールをシャーシの PXI Express スロットに取り付けます。 メモ 図 3 に示された 2 つの NI 5185/5186 モジュール上の PXI Express コネ クタは、 2 つの隣接した PXI Express スロットのシャーシバックプレーンに 接続する必要があります。 図 コネクタ 3. NI PXIe-5185/5186 PXI Express コネクタ...
  • Page 43: Ni Pxie-5185/5186 起動時の動作

    ウィザードを起動します。 ウィザードでの作業が完了すると、 NI 5185/5186 モジュー ルは約 5 〜 10 分間の初期化処理を⾏います。 初期化処理が完了してからモジュール を使用する必要があります。 メモ Access LED は、モジュールが構成できる状態になると緑色になりま す。 初期化処理は、その後 NI 5185/5186 を使用するたびに実⾏されますが、デバイス認識 ウィザードは各ブートサイクルでは表示されません。 モジュールは、オペレーティン グシステムが NI-SCOPE ドライバをロードした後で初期化処理を開始します。 PCI デバイス PCI デバイスを取り付けるには、以下の手順に従ってください。 コンピュータの電源を切り、電源プラグを抜きます。 PC のカバーを外します。 8 | ni.com | NI 高速デジタイザ スタートアップガイド...
  • Page 44 ( SMC 対応デバイス) めにプラスチックのレバーを使用するものもあります。このような場合、レバー は使用せずに、取り外す必要があります。 キットに含まれているネジを使用して デジタイザを固定してください。 ネジで固定することができない場合は、別のコ ンピュータシャーシを使用する必要があります。 PC のカバーを元どおりに取り付けます。 コンピュータの電源プラグを差し込み、電源を投入します。 拡散スペクトルクロックが PC の BIOS で有効になっている ( SMC 対応デバイス) か確認します。 確認する方法については、 PC のドキュメントを参照してくださ い。 メモ SMC 対応デバイスでは、拡散スペクトルクロックは、タイミングク ロック信号が狭い周波数範囲全体に渡るよう、クロック信号を分散します。 拡散スペクトルクロックを無効にすると、デバイスの確度に影響が出る可 能性があります。 NI 高速デジタイザ スタートアップガイド | © National Instruments | 9...
  • Page 45: Usb デバイス

    USB デバイス USB デバイスを取り付けるには、図 6 のように USB ケーブルを PC およびデジタイザ に接続します。 図 の取り付け 6. USB ノートブック NI USB 高速デジタイザ USB ケーブル 10 | ni.com | NI 高速デジタイザ スタートアップガイド...
  • Page 46: Usb ケーブルストレインリリーフ

    に押し込みます。 図 7 のように、 USB ケーブルのサイズに一致する溝を使用しま す。 ケーブルタイを使用 : 図 7 のように、 USB デバイスの下側にあるケーブルタイ取 • り付けバーにケーブルタイを通し、 USB ケーブルを固定します。 図 ケーブルストレインリリーフオプション 7. USB 固定溝を使用 USB ケーブル ケーブルタイを使用 ケーブルタイ USB ケーブルストレインリリーフ用溝(大) ケーブルタイ取り付けバー USB ケーブルストレインリリーフ用溝(小) NI 高速デジタイザ スタートアップガイド | © National Instruments | 11...
  • Page 47: Usb-5132/5133 を取り付ける

    NI USB-5132/5133 をデスクトップで使用、または標準 DIN レールまたはパネルに取 り付けることができます。 デスクトップでの使用 NI USB-5132/5133 の底部には、他の NI USB-5132/5133 デバイスを積み重ねることが できるように溝が付いています。 デスクトップで使用する場合にデバイスを安定させるには、図 8 のように、付属の 滑り止め用の脚をデバイスの下側に貼り付けます。 メモ NI USB-5132/5133 をパネルに取り付ける場合、または他の NI USB-5132/5133 デバイスの上に積み重ねる場合は、ゴム脚は使用しない でください。 図 ゴム脚を に取り付ける USB-513x NI USB 高速デジタイザ プラスチックガイド ゴム脚 12 | ni.com | NI 高速デジタイザ スタートアップガイド...
  • Page 48: Din レールマウント

    USB-513x をボードまたはパネルに取り付けるには、図 9 を参照しながら以下の手順 に従ってください。 図 をパネルに取り付ける 9. USB-513x メモ デバイスをパネルに取り付ける場合は、ゴム脚を USB-513x に取り付 けないでください。 メモ 「 USB ケーブルストレインリリーフ」セクションの説明どおり、 USB-513x をパネルに取り付ける前に、抜け防止対策を⾏います。 技術サポートデータベースのドキュメント「 USB-4065/5132/5133/6509 Panel Mounting Template 」に添付されているパネル取り付け用テンプレートの PDF をダウンロードして印刷します。 技術サポートデータベースのドキュメントを参 照するには、 で「 」のコードを入⼒します。 ni.com/jp/info rd3233 NI 高速デジタイザ スタートアップガイド | © National Instruments | 13...
  • Page 49: Windows のデバイス認識

    す。 デバイスを構成しテストするを選択すると、 MAX が開き、デバイスの構成を設 • 定できます。 何もしないを選択すると、デバイスの認識状態は維持されますが、アプリケー • ションは起動しません。 での構成とテスト 6. MAX メモ (NI 5185/5186) NI 5185/5186 をシャーシに取り付けた後、 Access LED は NI 5185/5186 がデバイスのファームウェアを構成してデバイスを初期化 している間⻩色に点灯します。 この間、ユーザはデバイスにアクセスする ことはできません。 Access LED が緑色に点灯すると、 MAX でのデバイス構 成を開始できます。 14 | ni.com | NI 高速デジタイザ スタートアップガイド...
  • Page 50 ステムについては、 『 NI-SCOPE Readme 』を参照してください。 MAX で割り当てられたデバイス番号またはデバイス名を記録します。この識別 子はデバイスのプログラミング時に必要となります。 デバイスのセルフテストを実⾏してインストールを検証します。 デバイスを右クリックして、セルフテストを選択します。 • デバイスを右クリックし、構成を選択 (従来型 NI-DAQ( レガシー ) デバイス) • し、リソース確認を選択します。 ダイアログボックスが開き、デバイスのテストの結果が表示されます。 メモ デバイスのセルフテストが不合格になった場合は、 「 5. ハードウェア を取り付ける」のセクションの手順を再度⾏ってください。 それでも不合 格になる場合は、ナショナルインスツルメンツの技術サポートのウェブサ イト( )を参照してください。 ni.com/support NI 高速デジタイザ スタートアップガイド | © National Instruments | 15...
  • Page 51: デバイスをプログラミングする

    入門セクション(スタート→すべてのプログラム→ National Instruments → NI-SCOPE →ドキュメント→ NI 高速デジタイザヘルプ)を参照してください。 NI 起動ツールをクリックして、表示されるウィンドウで NI-SCOPE → (Windows 8) ドキュメント→ NI 高速デジタイザヘルプを選択します。 ヒント NI-SCOPE C のサンプルを変更して Microsoft Visual C/C++ でアプ リケーションを作成することができ、その場合、必要なインクルードファ イルおよびライブラリファイルはすべて自動的にプロジェクトに追加され ます。 すべての必要なインクルードファイルおよびライブラリファイルを 手作業でプロジェクトに追加したい場合は、 『 NI 高速デジタイザヘルプ』 16 | ni.com | NI 高速デジタイザ スタートアップガイド...
  • Page 52: Ni-Scope サンプル

    ADE を起動します。 スタート→すべてのプログラム→ National Instruments → NI-SCOPE →サンプル を選択して、サンプルを開きます。 (Windows 8) NI 起動ツールをクリックして、 NI-SCOPE →サンプルを選択します。 どのサンプルを実⾏するか不明な場合は、 Getting Started サンプルを選択してください。 リソース名制御器またはパラメータに適切な文字列を入⼒します。 この文字列 は、デジタイザが従来型 NI-DAQ デバイスである場合は異なります。 デバイス名 の詳細については、以下のリソースを参照してください。 本ドキュメントのセクション「 6. MAX での構成とテスト」 • NI 高速デジタイザ スタートアップガイド | © National Instruments | 17...
  • Page 53: 付録 A: Smc 対応デバイスおよび Usb デバイスのフロントパネル

    この付録では、 SMC 対応デバイスおよび USB デバイス NI 5105 、 NI 5114 、 NI 5122 、 NI 5124 、 NI 5132 、 NI 5133 、 NI 5142 、 NI 5152 、 NI 5153 、 NI 5154 、 NI 5160 、 NI 5162 、...
  • Page 54: Ni 5105 フロントパネル

    NI 5105 フロントパネル 図 11 は、 NI PXI-5105 および NI PCI-5105 のフロントパネルを示します。 図 フロントパネル 11. NI 5105 NI PXI-5105 NI PCI-5105 12-Bit 60 MS/s Digitizer CH 0 CH 0 CH 1 CH 1 CH 2 CH 2 CH 3 CH 3...
  • Page 55: Ni 5114 フロントパネル

    NI 5114 フロントパネル 図 12 は、 NI PXI-5114 および NI PCI-5114 のフロントパネルを示します。 AUX コネクタ のピン配列情報については、図 14 を参照してください。 図 フロントパネル 12. NI 5114 NI PXI-5114 CH 0 CH 0 CH 1 CH 1 TRIG TRIG CLK IN CLK IN AUX I/O...
  • Page 56: Ni 5122/5124/5142/5922 フロントパネル

    PFI 1 ブルが必要) 。 ピン配列に関する情報について は、図 を参照のこと。 NI 5122/5124/5142/5922 フロントパネル 図 13 は、 NI PXI-5122/5124/5142/5922 および NI PCI-5122/5124/5142/5922 のフロン トパネルを示します。 NI PXI-5122 および NI PXIe-5122 のフロントパネルは同じです。 図 フロントパネル 13. NI 5122/5124/5142/5922 NI 高速デジタイザ スタートアップガイド | © National Instruments | 21...
  • Page 57 PFI 1 ブルが必要) 。 ピン配列に関する情報について は、図 を参照のこと。 9 ピン DIN コネクタピンの割り当ては、図 14 のとおりです。 図 の ピン コネクタピンの割り当て 14. NI 5114/5122/5124/5142/5922 +5 V ( ヒューズ付き ) 予約済み 予約済み 予約済み 予約済み 予約済み PFI 1 PFI 0 22 | ni.com | NI 高速デジタイザ スタートアップガイド...
  • Page 58: Ni 5132/5133 フロントパネル

    NI 5132/5133 フロントパネル 図 15 は、 NI USB-5132 および NI USB-5133 のフロントパネルを示します。 図 フロントパネル 15. NI 5132/5133 CH 0 CH 1 PFI 1 NI USB-5132 8-bit, 50 MS/s Digitizer CH 0 CH 1 PFI 1 NI USB-5133 8-bit, 100 MS/s Digitizer 図...
  • Page 59: Ni 5152/5153/5154 フロントパネル

    NI 5152/5153/5154 フロントパネル 図 17 は、 NI PXI-5152/5153/5154 および NI PCI-5152/5153/5154 のフロントパネルを 示します。 図 フロントパネル 17. NI 5152/5153/5154 ACCESS ACTIVE CH 0 TRIG TRIG CH 1 PFI 0 PFI 1 PFI0 PFI1 表 5 は、 NI 5152/5153/5154 の信号接続を示します。 表 フロントパネルの信号接続...
  • Page 60: Ni 5160/5162 フロントパネル

    NI 5160/5162 フロントパネル NI 5160/5162 ( 2 CH ) 図 18 は、 NI 5162 ( 2 CH )のフロントパネルを示します。 図 ( )フロントパネル 18. NI 5160/5162 2 CH NI PXIe-5160 NI PXIe-5162 10-Bit 2.5 GS/s 10-Bit 5 GS/s 500 MHz Digitizer 1.5 GHz Digitizer...
  • Page 61 ジャック デジタルトリガ入出⼒。 PFI 1 標準 ジャック デジタルトリガ入出⼒、プローブ補正。 NI 5160/5162 ( 4 CH ) 図 19 は、 NI 5160/5162 ( 4 CH )のフロントパネルを示します。 図 ( )フロントパネル 19. NI 5160/5162 4 CH 表 7 は、 NI 5160/5162 ( 4 CH )の信号接続を示します。 表...
  • Page 62: Ni 5185/5186 フロントパネル

    ± 42 V MAX ±5 V ±5 V 50Ω 50Ω 表 8 は、 NI 5185/5186 の信号接続を示します。 表 フロントパネルの信号接続 8. NI 5185/5186 コネクタ 説明 機能 REF CLK ジャックコネクタ 外部基準クロックをデジタイザにインポート。 (標準) CLK IN メスコネクタ 外部サンプルクロックをデジタイザにイン ポート。 NI 高速デジタイザ スタートアップガイド | © National Instruments | 27...
  • Page 63: 旧バージョン Ni 5185/5186 モジュール

    旧バージョンの NI 5185/5186 では、 50 Ω の入⼒インピーダンスのみをサポートしま す。 NI 5185/5186 のフロントパネルが上に表示されたフロントパネルと異なる場合、 ご使用のデバイスは古い型番である可能性があります。 デバイスの製品番号で確認し てください。 NI 5185 モジュール(製品番号 199363x-0zL )および NI 5186 モジュール(製品番 • 号 193537x-0zL ) ( x は文字、 z は数字)は、 50 Ω 入⼒インピーダンスのみをサ ポートします。 NI 5185 モジュール(製品番号 152962x-0zL )および NI 5186 モジュール(製品番...
  • Page 64: Ni 5622 フロントパネル

    表 フロントパネルの信号接続 9. NI 5622 コネクタ 説明 機能 IF IN メスコネクタ アナログ入⼒接続。データのデジタル化とトリ ガ集録。 PFI 1 ジャックコネクタ デジタルトリガ接続。 (基準クロック入⼒、サ ンプルクロック入⼒、デジタルトリガ入出⼒用 の汎用 ライン) CLK IN メスコネクタ 外部基準クロックまたはサンプルクロックをデ ジタイザにインポート。 CLK OUT ジャックコネクタ デジタイザの基準クロックまたはサンプルク ロックをエクスポート。 NI 高速デジタイザ スタートアップガイド | © National Instruments | 29...
  • Page 65: 付録 B: 従来型 Ni-Daq (レガシー)用デバイスのフロントパネル

    ±3 VDC MAX REF CLK IN REF CLK IN +16 dBm MAX +20 dBm MAX ±10 VDC MAX ±10 VDC MAX PFI 1 PFI 1 TTL (+5 V MAX) TTL (+5 V MAX) 30 | ni.com | NI 高速デジタイザ スタートアップガイド...
  • Page 66: 付録 C: アクセサリのフロントパネル

    ( NI 5620 ) 50 Ω 、 カプリング。 ( NI 5621 ) 50 Ω REF CLK IN メスコネクタ(標準) 、 、 カプリング基準クロック 50 Ω 10 MHz 入⼒。 PFI 1 ジャックコネクタ(標準) 外部デジタルトリガ接続。 付録 アクセサリのフロントパネル この付録には、デジタイザアクセサリのフロントパネルおよび信号接続が記載されて います。 NI 高速デジタイザ スタートアップガイド | © National Instruments | 31...
  • Page 67: Ni 5900 フロントパネル

    NI 5900 フロントパネル 図 23 は、 NI PXI-5900 差動アンプのフロントパネルおよび NI 5922 との接続を示します。 図 フロントパネル 23. NI 5900 NI PXI-5922 NI PXI-5900 CH 0 + CH 0 - OUT 0 CH 1 + CH 1 - OUT 1 表 11 は、 NI 5900 の信号接続を示します。...
  • Page 68: 付録 D: トラブルシューティング

    )にお問い合わせください。 ni.com/support USB モジュールが接続されていても USB モジュールの バックパネル LED が点灯しない USB ポートに接続してもデジタイザの LED が点灯しない場合は、ソフトウェアのイ ンストール、ハードウェアデバイス、 LED のいずれかに問題がある可能性がありま す。 メモ LED は、 MAX でのデバイスの構成が完了しないと点灯しないことが あります。この問題のトラブルシューティングを開始する前に、 MAX でこ のデバイスが表示されるか確認してください。 この問題のトラブルシューティングは、以下の手順で⾏ってください。 USB デジタイザの電源プラグを抜きます。 USB デジタイザのフロントパネルへの信号接続をすべて取り外します。 NI 高速デジタイザ スタートアップガイド | © National Instruments | 33...
  • Page 69: デバイスが Max で表示されない

    スツルメンツの技術サポート( )にお問い合わせください。 ni.com/support デバイスがセルフテストで不合格になる MAX のセルフテストでは、デバイスリソースを確認します。 セルフテストでデバイ スが不合格になった場合は、以下の手順に従ってください。 コンピュータを再起動します。 MAX を起動し、再度セルフテストを実⾏します。 上記の手順を⾏ってもデバイ スがセルフテストに合格しない場合は、手順 3 に進んでください。 NI-SCOPE をアンインストールし、再インストールします。 それでもセルフテストに合格しない場合は、ナショナルインスツルメンツの技術 サポート( )にお問い合わせください。 ni.com/support 過熱遮断エラー 過熱(または過熱遮断)によりエラーが発生し、デバイスが停止した場合は、以下の 方法に従ってデバイスを再度有効にします。 デバイスが取り付けられているコンピュータまたはシャーシの電源を切ります。 「 5. ハードウェアを取り付ける」セクションの手順を再度確認し、デバイスを効 果的に冷却するための手順を必要に応じて追加します。 コンピュータまたはシャーシの電源を投入します。 メモ 過熱遮断エラーは、デバイスが適切な動作温度に戻り、また、正常 にリセットされるまで発生し続けます。 34 | ni.com | NI 高速デジタイザ スタートアップガイド...
  • Page 70: Mxi 接続時におけるパフォーマンスの問題

    ( PXI および PXI Express モジュール) ローラを認識する必要があります。 MAX のツリー構図で PXI システム→次のモデルとして識別を右クリックします。 一覧からコントローラを選択します。 たとえば、 PC から MXI コントローラ を使用する場合は、 「外部 PC 」を選択します。 PXI システムツリーを展開し、使用するシャーシの名前を右クリックします。 以下の手順に従って RTSI ケーブルを構成する必要があります。 ( PCI デバイス) PCI デバイス間を RTSI ケーブルで接続して、トリガ / クロックを物理的に共有し ます。 NI 高速デジタイザ スタートアップガイド | © National Instruments | 35...
  • Page 71: 付録 E: サポート情報

    Guidelines 」 をご覧下さい。本文書中に記載されたその他の製品名および企業名は、それぞれの企業の商標または商号です。 National Instruments の製品 / 技術を保護する特許については、ソフトウェアで参照できる特許情報 ( ヘルプ→特許情報 ) 、メ ディアに含まれている patents.txt ファイル、または「 National Instruments Patent Notice 」 ( ni.com/patents )のうち、該 当するリソースから参照してください。エンドユーザ使用許諾契約( EULA )に関する情報および他社製品の法的注意事項はご 使用の NI 製品の Readme ファイルにあります。ナショナルインスツルメンツの輸出関連法規遵守に対する方針について、ま た必要な HTS コード、 ECCN 、その他のインポート / エクスポートデータを取得する方法については、 「輸出関連法規の遵守に...

Table of Contents