Change Filter Element Of Equipment; Emergency Switch; Change The Fuse - MBT Vaca Shape User Manual

Table of Contents

Advertisement

4) Dry the place with warm wind where you could not touch;

6.2 Change Filter Element of Equipment

1) When the equipment works for one or two months, you have to change for new filter elements;
2) Unscrew A and B on the back of the equipment(Picture 6.2-1)and take out the filter elements;
3) Put a new filter element on A/B;
Note: The holes (C and D) shall well abutting joint;
4) Screw A and B
A

6.3 Emergency Switch

Turn on the equipment, when you press the emergency switch, the system will turn off at once;
Turn the emergency switch and start the equipment;

6.4 Change the Fuse

1)
Turn off equipment, turn off electricity breaker, unplug the power wire from the socket;
2)
Unscrew the fuse house on the back panel;
3)
Take out the two fuses from fuse house and change for new ones of the same specifications;
4)
Screw the fuse house ;
5)
Connect power wire and turn on electricity breaker;
6)
Turn on equipment.
17//22
Tip
Picture 6.1-5
B
Picture 6.2-1
A
B
D
C
Filter element
A/B
All rights reserved