Pinnacle International MASTER MH-45-KFA User's Manual & Operating Instructions page 13

Advertisement

Your serial number can be found on a white label on the right side cover of your heater. It will begin
ready before calling customer service at 800-641-6996.
Problem
Heater Ignites, but main PCB shuts
off after a short period of time.
shows "E1".
Heater will not operate or motor
runs for a short time.
shows "E1".
Fan does not operate when heater
is plugged in and power switch is
in the "ON" position. The lamp is
"E1" or "E2".
soot production.
Heater does not turn on and the
lamp is not lit.
© 2015, Pinnacle Products International, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
Possible Cause
1. Incorrect pump pressure.
2.
4. Nozzle is dirty.
5. Photocell lens is dirty.
6. Photocell not installed properly.
7. Photocell is defective.
8. Improper electrical connection
between main PCB and photocell.
1. No kerosene in the fuel tank.
2. Incorrect pump pressure.
Corroded spark plug or incorrect
plug gap.
4.
5. Dirty nozzle.
6. Moisture in fuel tank.
7. Improper electrical connection
between transformer and circuit
board.
8. Ignitor wire not connected to spark
plug.
9. Defective ignitor.
1. Thermostat is set too low (does not
apply to 45-KFA model).
2. Broken electrical connection
between main PCB and motor.
1. Thermostat switch has failed.
1.
2.
Poor quality of fuel.
4. PSI is too high or too low.
1. Temperature limit sensor has
overheated.
2. No electrical power.
Fuse is blown.
4. Improper electrical connection
between temperature limit sensor
and circuit board.
12
1. Adjust pump pressure.
2.
4.
5.
6. Adjust photocell position
7. Replace photocell
8. Check wiring connections
(see wiring diagrams on page 11).
1. Fill tank with fresh kerosene.
2. Adjust pump pressure.
4.
5.
6. Rinse fuel tank with clean, fresh
kerosene.
7. Inspect all electrical connections.
(See wiring diagrams on page 11.)
8. Re-attach ignitor wire to spark plug.
9. Replace ignitor.
1. Rotate thermostat to a higher
setting
2. Inspect all electrical connections
(see wiring diagrams on page 11).
1. Replace thermostat switch (see
Wiring diagrams on page 11).
1.
2.
Flush fuel tank and refuel heater.
4. Use proper pressure.
1. Push power switch to "OFF and
allow heater to cool for 10 minutes.
Restart heater.
2. Check power cords for proper
connection and test the power
supply.
4. Inspect all electrical connections
(see wiring diagrams on page 11).
Kerosene Forced Air Heater User's Manual