Pinnacle International Protemp PT-70-SS-A User's Manual & Operating Instructions

Pinnacle International Protemp PT-70-SS-A User's Manual & Operating Instructions

Table of Contents

Advertisement

Available languages

Available languages

Quick Links

CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING:
DANGER
READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL
BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the
instructions and warnings provided with this heater. Failure to comply can result in fire or explosion
that can cause property loss, bodily injury, or loss of life. Only persons who can follow and
understand these instructions should operate or service this heater. If you need heater info; such as
an operating manual, labels, etcetera, contact Pinnacle Products International at 800-641-6996.
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES
DANGER
WITHOUT ADEQUATE VENTILATION. FOR OUTDOOR USE. INDOOR USE
PERMITTED ONLY FOR: THE TEMPORARY HEATING OF ADEQUATELY VENTILATED
BUILDINGS OR STRUCTURES UNDER CONSTRUCTION, ALTERATION OR REPAIR. This is
an unvented portable heater that uses air (Oxygen) from within the area in which it is used. Failure
to provide adequate combustion and ventilation air will result in asphyxiation, carbon monoxide
poisoning, bodily injury or death. Refer to "Ventilation" on Page 6.
Fax: (215)-891-8461
Model Numbers
PT-70-SS-A / PT-125-OFR-A
© 2015 Pinnacle Products International, Inc.
668 Stony Hill Road #302 Yardley, PA 19067 USA
• Web: www.protemp.us • Email: info@pinnacleint.com
User's Manual &
Operating Instructions
®
Factory ID: 001
751000250-14

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Pinnacle International Protemp PT-70-SS-A

  • Page 1 User’s Manual & Operating Instructions ® Model Numbers PT-70-SS-A / PT-125-OFR-A Factory ID: 001 CONSUMER: READ AND SAVE THESE INSTRUCTIONS GENERAL HAZARD WARNING: DANGER READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the instructions and warnings provided with this heater.
  • Page 2: Table Of Contents

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Table Of Contents Safety Information..........1-2 Troubleshooting Guide........13 Features and Specifications......3-4 Wiring Diagrams..........14 Assembly............5-8 Exploded Views..........15,17 Ventilation.............9 Parts List............16,18 Operation............9-10 Warranty.............19 Maintenance..........11-12 Safety Information FIRE, BURN, INHALATION AND EXPLOSION HAZARD. Keep combustibles such WARNING as;...
  • Page 3: Safety Information

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Safety Information RISK OF INDOOR AIR WARNING WARNING RISK OF ELECTRIC SHOCK! POLLUTION! ALWAYS use only the electrical power (voltage and frequency) specified on the model plate of the heater. The products described in this manual are Kerosene/Diesel direct-fired, forced air heaters.
  • Page 4 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Specifications Model # PT-70-SS-A PT-125-OFR-A Rating: Btu/Hr 70,000 125,000 Fuel Consumption: G/Hr 0.50 0.85 Fuel Tank Capacity: G Max Operating Hours Volts: AC/Hz 120V / 60Hz 120V / 60Hz Amps Heating Area m 1,750...
  • Page 5 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Features PT-125-OFR-A Top Safety Guard Radiant Cone Handle Front Safety Guard Radiant Fuel Cap Visors Wheel Frame Adjustment Knob º Can Tilt Up To 15° Drain Bolt Wheel ©...
  • Page 6 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Assembly Instructions PT-70-SS-A Note: Save the box and packaging materials - Remove the heater and all packaging materials from the shipping carton. for future storage. What’s In The Box Carry Handle (1) Black Screws (2) Carry Handle Assembly...
  • Page 7: Assembly

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Assembly IMPORTANT: – INSTALL HEAT SHIELD BEFORE OPERATING YOUR PT-70-SS HEATER Step 1: Remove existing screws from shell ring on either side of heater. Step 2: Line up holes on heat shield with holes in shell ring.
  • Page 8 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Assembly Instructions PT-125-OFR-A - Remove the heater and all packaging materials Note: Save the box and packaging materials from the shipping carton. for future storage. What’s In The Box Long Screws (6) Short Screws (4) 8 mm Nuts (6)
  • Page 9 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Assembly 4. Attach Radiant Visors to the top and bottom 1. Slide axle through Wheel Frame and attach rear of the Radiant Cone Assembly using extra wheels, washers and nuts. screws included.
  • Page 10: Ventilation

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Operation Fueling The Heater: Ventilation: Kerosene - Risk of indoor air pollution and Carbon For optimal performance of this heater, it is Monoxide Poisoning. Use heater only in well strongly suggested that Kerosene be used.
  • Page 11 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Operation: PT-70-SS-A / PT-125-OFR-A Starting the Heater: (Ignition) Stopping the Heater: (Cool Down) 1. Fill the tank with Kerosene or other approved 1. Turn the power switch to the “OFF” position. fuel until needle on fuel gauge points to “F”.
  • Page 12: Maintenance

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Maintenance: PT-70-SS-A / PT-125-OFR-A Long Term Storage: SPARK PLUG: Clean and re-gap every 600 hours of operation 1. Unscrew the fuel cap. or replace as needed. After removing the Spark 2.
  • Page 13 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Maintenance: PT-70-SS-A / PT-125-OFR-A Service (Continued): PHOTOCELL: The photocell should be cleaned at least once NOZZLES: per heating season or more depending on Nozzles should be cleaned or replaced at least conditions.
  • Page 14: Troubleshooting Guide

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Troubleshooting Guide: PT-70-SS-A / PT-125-OFR-A Problem Possible Cause Solution 1. Dirty Fuel Filter. 1. Clean/replace Fuel Filter. 2. Nozzle Dirty. 2. Clean/replace Nozzle 3. Photocell Dirty. 3. Clean/replace Photocell . 4.
  • Page 15 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Wiring Diagram PT-70-SS-A AC 120V/60Hz AC 125V 3.15A ELECTRIC OUTLET PT-125-OFR-A Figure 12 © 2015, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 16: Exploded Views

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Exploded View PT-70-SS-A Figure 13 © 2015, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 17: Parts List

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Parts List: PT-70-SS-A Item # Description PT-70-SS-A Fuel Tank Assembly 75-001-0350 Oil Filter Assembly 75-023-0270 Fuel Pipe 75-023-0345 Fuel Packing 75-023-0355 Fuel Hose 75-024-0510 Fuel Gauge Assembly 75-022-0210 Fuel Cap Assembly 75-002-0110...
  • Page 18 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Exploded View PT-125-OFR-A © 2015, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 19 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Parts List: PT-125-OFR-A Item # Description PT-70-SS-A Fuel Tank Assembly 72-001-0200 Fuel Filter 72-022-0130 Fuel Tank Cap Assembly 72-002-0150 Wheel 72-041-1400 Axle 72-041-0200 Wheel Frame 72-042-0120 Drain Bolt 72-002-0220 Transport Handle 72-042-0220...
  • Page 20: Warranty

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE LIMITED WARRANTY Pinnacle Products International, Inc. warrants this heater If Pinnacle Products International, Inc. finds the item to to the original retail purchaser only, to be free from defects be in normal operating condition, or not defective the item in material and workmanship for a period of one (1) year will be returned freight collect.
  • Page 21 Manual del Usuario e Instrucciones de ® Operación Modelos No. PT-70-SS-A / PT-125-OFR-A Factory ID: 001 CONSUMIDOR: GUARDE ESTE MANUAL PARA FUTURAS CONSULTAS ADVERTENCIA DE PELIGRO GENERAL: ANTES DE ENSAMBLAR, ARRANCAR O REALIZAR SERVICIO TÉCNICO AL CALENTADOR, LEA Y COMPRENDA TODAS LAS INSTRUCCIONES EN ESTE MANUAL. Asegúrese de seguir las instrucciones y advertencias provistas con este calentador.
  • Page 22 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Tabla de Contenidos Información Sobre Seguridad......1-2 Guía de Solución de Problemas......13 Características y Especificaciones....3-4 Diagramas Eléctricos.........14 PT-70-SS-A Montaje.........5-8 Dibujo de Despiece de Piezas......15,17 Ventilación............9 Lista de Recambios ........16,18 Operación............9-10...
  • Page 23: Información Sobre Seguridad

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Información Sobre Seguridad ¡RIESGO DE CONTAMINACIÓN ¡PELIGRO DE ELECTROCUCIÓN! DEL AIRE INTERIOOR! Los productos descritos en este manual son calentadores de aire forzado e impulsados SIEMPRE use solamente la energía eléctrica (voltaje y frecuencia) especificada en la placa de modelo del directamente a kerosén.Los calentadores de aire...
  • Page 24 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Especificaciones Modelo # PT-70-SS-A PT-125-OFR-A Potencia Térmica: Btu/Hr 70,000 125,000 Consumo de Combustible 0.85 Capacidad del Despotivo: G Horas Máximas de Funcionamiento Voltaje: AC/Hz 120V / 60Hz 120V / 60Hz Amperaje...
  • Page 25 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Características PT-125-OFR-A Protección de pared encima Cono Radiante Mango Protección de pared en frente Tapa del tanque Visores de combustible Radiantes Marco de las Ruedas La perilla de ajuste º...
  • Page 26 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Instrucciones de Montaje PT-70-SS-A Nota: Guarde la caja y los materiales de - Retire el calentador y los materiales de embalaje de la caja de envío embalaje para almacenamiento futuro..
  • Page 27 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Montaje IMPORTANTE: – INSTALE EL ESCUDO DE CALOR ANTES DE PONER A FUNCIONAR SU CALENTADOR 70-SS Paso 1: Retire los tornillos existentes del anillo de la carcasa en ambos lados del calentador Paso 2: Alinee los orificios en el escudo de calor...
  • Page 28 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Instrucciones de Montaje PT-125-OFR-A - Retire el calentador y los materiales de Nota: Guarde la caja y los materiales de embalaje de la caja de envío embalaje para almacenamiento futuro.
  • Page 29 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Montaje 4. Sujete los visores radiantes a la parte 1. Deslice el eje a través del marco de las ruedas posterior, inferior y superior, del conjunto del y sujete las ruedas, arandelas y tuercas.
  • Page 30: Ventilación

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Operación Cómo Llenar Comustible en el Calentador: Kerosén (1-K) NOTA: El keroseno debe almacenarse Para el rendimiento óptimo de este calentador, únicamente en un contenedor azul que se sugiere firmemente que se use kerosén 1-K.
  • Page 31 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Operación Encendido del calentador: (Ignición) 2. Mueva el interruptor de encendido a la posición “On”. La luz indicadora de energía se iluminará y 1.
  • Page 32: Mantenimiento

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Mantenimiento Almacenamiento a Largo Plazo: BUJÍA: Límpiela y reajuste la separación entre los 1. Desatornille la tapa del tanque de combustible. electrodos de la bujía después de cada 600 horas 2.
  • Page 33 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Mantenimiento Servicio (Continuación): FOTOCÉLULA: BOQUILLAS: La fotocélula debe limpiarse al menos una vez Las boquillas deben limpiarse o reemplazarse por cada temporada de calefacción o más, al menos una vez por cada temporada de dependiendo de las condiciones.
  • Page 34: Guía De Solución De Problemas

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Guía de Solución de Problemas Problema Causa posible Solución Filtro de combustible sucio Limpie o reemplace el filtro de combustible Boquilla sucia Limpie o reemplace la boquilla Fotocélula sucia El calentador se enciende, pero se Limpie o reemplace la fotocélula...
  • Page 35: Diagramas Eléctricos

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Diagramas Eléctricos PT-70-SS-A AC 125V 3.15A PT-125-OFR-A Figura 12 BOMBILLA DE ENCHUFE DE ALIMENTACIÓN FUNCIONAMIENTO / AC 120V/60Hz FUSIBLE BOMBILLA DE COMPROBACIÓN AC 120 DE ERROR 3.15 A TIERRA...
  • Page 36: Dibujo De Despiece De Piezas

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Dibujo de Despiece de Piezas PT-70-SS-A Figura 13 © 2015, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 37: Lista De Recambios

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Lista de Recambios Item # Description PT-70-SS-A Tanque de Combustible 75-001-0350 Conjunto del Filtro de Aceite 75-023-0270 Aabstezca de Combustible Tubo 75-023-0345 Aabstezca de Combustible Empacar 75-023-0355 Manguera De Entrada 75-024-0510...
  • Page 38 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Dibujo de Despiece de Piezas PT-125-OFR-A © 2015, Pinnacle Products International, Inc. Oil Fired Radiant Heater User’s Manual...
  • Page 39 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Item # Description PT-70-SS-A Tanque de Combustible 72-001-0200 Filtro de Combustible 72-022-0130 Conjunto de la tapa del tanque de combustible 72-002-0150 Rueda 72-041-1400 72-041-0200 Marco de las Ruedas 72-042-0120...
  • Page 40 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN GARANTÍA LIMITADA Pinanacle Products International, Inc. le garantiza porte pagado. Si Pinnacle Products International, Inc. exclusivamente al comprador minorista original de este determina que el artículo está en condición normal de calentador que no tendrá...

This manual is also suitable for:

Protemp pt-125-ofr-a

Table of Contents