Pinnacle International Protemp PT-150T-DFV User's Manual & Operating Instructions

Pinnacle International Protemp PT-150T-DFV User's Manual & Operating Instructions

Table of Contents

Advertisement

Available languages

Available languages

Quick Links

CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING:
DANGER
READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL
BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the
instructions and warnings provided with this heater. Failure to comply can result in fire or explosion
that can cause property loss, bodily injury, or loss of life. Only persons who can follow and
understand these instructions should operate or service this heater. If you need heater info; such as
an operating manual, labels, etcetera, contact Pinnacle Products International at 800-641-6996.
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES
DANGER
WITHOUT ADEQUATE VENTILATION. INDOOR USE PERMITTED ONLY FOR
THE TEMPORARY HEATING OF BUILDINGS OR STRUCTURES UNDER CONSTRUCTION,
ALTERATION OR REPAIR. This is an unvented portable heater that uses air (Oxygen) from within
the area in which it is used. Failure to provide adequate combustion and ventilation air will result in
asphyxiation, carbon monoxide poisoning, bodily injury or death. Refer to "Ventilation" on Page 6.
668 Stony Hill Road #302 Yardley, PA 19067 USA
Fax: (215)-891-8461
Model Numbers
PT-150T-DFV / PT-220T-DFV
HEATER SHOWN WITHOUT SAFETY GUARD. PLEASE
ATTACH SAFETY GUARD BEFORE USING HEATER.
© 2014 Pinnacle Products International, Inc.
• Web: www.Protemp.us • Email: info@pinnacleint.com
User's Manual &
Operating Instructions
®
Toll Free (800)-641-6996

Advertisement

Table of Contents
loading

Summary of Contents for Pinnacle International Protemp PT-150T-DFV

  • Page 1 User’s Manual & Operating Instructions ® Model Numbers PT-150T-DFV / PT-220T-DFV HEATER SHOWN WITHOUT SAFETY GUARD. PLEASE ATTACH SAFETY GUARD BEFORE USING HEATER. CONSUMER: READ AND SAVE THESE INSTRUCTIONS GENERAL HAZARD WARNING: DANGER READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER.
  • Page 2: Table Of Contents

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Table Of Contents Safety Information..........1-2 Wiring Diagram..........10 Features and Specifications.........3 Troubleshooting Guide........11 Assembly............4-5 Exploded View...........12 Operation............6-7 Parts List............13-14 Ventilation.............6 Warranty.............15 Storage..............8 Safety Information FIRE, BURN, INHALATION AND EXPLOSION HAZARD. Keep combustibles such WARNING as;...
  • Page 3: Safety Information

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Safety Information RISK OF INDOOR AIR WARNING WARNING RISK OF ELECTRIC SHOCK! POLLUTION! ALWAYS use only the electrical power (voltage and The products described in this manual are frequency) specified on the model plate of the heater.
  • Page 4 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Specifications Model # PT-150T-DFV PT-220T-DFV Rating: Btu/Hr 120,000 / 150,000 170,000 / 220,000 Fuel Consumption: Gal/Hr 0.91 / 1.14 1.29 / 1.67 Fuel Tank Capacity: Gallons Pump Pressure: PSI 71 / 111 56 / 93...
  • Page 5: Assembly

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Assembly Instructions Model: PT-150T-DFV / PT-220T-DFV Remove the heater and all packaging Tools Needed: materials from the shipping carton. - Phillips Head Screw Driver - 8 mm open end wrench Tip: Be sure to remove the axle from the - 19 mm open end wrench side of the Styrofoam packaging.
  • Page 6 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Assembly Instructions Models: PT-150T-DFV / PT-220T-DFV 1. Place heater on saw horses or work bench for easier assembly. Tip: Assembling your heater on saw Handle horses will make it easier to attach the wheel support frame.
  • Page 7: Operation

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Operation Fueling The Heater: NOTE: Kerosene should only be stored in a blue Kerosene (1-K) container that is clearly marked “Kerosene.” For optimal performance of this heater, it is Never store kerosene in a red container.
  • Page 8 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Operation Starting the Heater: (Ignition) Control Panel: 1. Fill the tank with kerosene or other approved fuel until needle on fuel gauge points to “F”. 2. Replace fuel cap and tighten firmly. 3.
  • Page 9: Storage

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Maintenance Long Term Storage: Service: Never service heater while it is WARNING 1. Drain fuel through the drain plug in the bottom plugged in or hot! of the fuel tank.
  • Page 10 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Maintenance Service (Continued): SPARK PLUG: FAN BLADES: Clean and re-gap every 600 hours of operation, or Blades should be cleaned at least once per replace as needed. After removing the spark plug, heating season, depending on conditions.
  • Page 11: Wiring Diagram

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Maintenance NOZZLES: Nozzles should be cleaned or replaced at least once per heating season. Contaminated fuel could make this necessary immediately. To clean dirt from nozzle, blow compressed air through nozzle front.
  • Page 12: Troubleshooting Guide

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Troubleshooting Guide Locating Your Serial Number: Your serial number can be found on a white label on the right side cover of your heater. It will begin with 2 digits, the letter “H”...
  • Page 13: Exploded View

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Exploded View © 2014, Pinnacle Products International, Inc. Dual Fusion Forced Air Heater User’s Manual...
  • Page 14: Parts List

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Parts List Item # Description PT-150T-DFV PT-220T-DFV Front Shell 70-001-5000 70-001-5005 Combustion Chamber 70-011-1000 70-011-1010 Upper Shell 70-001-5010 70-001-5010 Chamber Baffle 70-011-1050 70-011-1060 Shell Side Cover 70-008-1000 70-008-1000 Control PCB...
  • Page 15 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® Parts List Item # Description PT-150T-DFV PT-220T-DFV Return Fuel Line 70-036-2100 70-036-2100 Fuel Cap 70-006-0120 70-006-0120 Fuel Gauge 70-007-0215 70-007-0216 Fuel Filter 70-003-1000 70-003-1000 Fuel Tank 70-002-1000 70-002-1100 Power Cord...
  • Page 16: Warranty

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE ® LIMITED WARRANTY Pinnacle Products International, Inc. warrants this heater If Pinnacle Products International, Inc. finds the item to to the original retail purchaser only, to be free from defects be in normal operating condition, or not defective the item in material and workmanship for a period of one (1) year will be returned freight collect.
  • Page 17 © 2014 Pinnacle Products International, Inc. 668 Stony Hill Road #302 Yardley, PA 19067 USA • Toll Free (800)-641-6996 Fax: (215)-891-8461 • Web: www.pinnacleint.com • Email: info@pinnacleint.com...
  • Page 18 Manuel de L’utilisateur et Instructions D’utilisation ® Numéros de Modèles PT-150T-DFV / PT-220T-DFV APPAREIL DE CHAUFFAGE ILLUSTRÉ SANS LE GARDE DE SÉCURITÉ. VEUILLEZ ATTACHER LE GARDE DE SÉCURITÉ AVANT D’UTILISER L’APPAREIL DE CHAUFFAGE. CLIENT: CONSERVER CE MANUEL POUR CONSULTATION ULTÉRIEURE NOTE D’AVERTISSEMENT GÉNÉRAL: VEUILLEZ LIRE ET COMPRENDRE TOUTES LES INSTRUCTIONS DE CE MANUEL AVANT D’ASSEMBLER, DE METTRE EN MARCHE OU DE FAIRE EFFECTUER DES...
  • Page 19 NE JAMAIS LAISSER LE RADIATEUR SANS SURVEILLANCE ALORS QU’IL EST EN MARCHE OU QU’IL EST RACCORDÉ ® À UNE SOURCE D’ALIMENTATION. Table de Matières Informations sur la Sécurité......1-2 Schéma de Câblage...........10 Caractéristiques...........3 Dépannage............11 Assemblage.............4-5 Vue Éclatée des Pièces........12 Fonctionnement..........6-7 Liste des Pièces..........13-14 Ventilation.............6 Garantie.............15 Entretien............8-10...
  • Page 20: Informations Sur La Sécurité

    NE JAMAIS LAISSER LE RADIATEUR SANS SURVEILLANCE ALORS QU’IL EST EN MARCHE OU QU’IL EST RACCORDÉ ® À UNE SOURCE D’ALIMENTATION. Informations sur la Sécurité RISQUE DE POLLUTION DE RISQUE DE CHOC ÉLETRIQUE! L’AIR INTÉRIEUR! TOUJOURS utiliser uniquement l’alimentation électrique Les produits décrits dans ce manuel sontdes générateurs (tension et fréquence) indiquée sur la plaque signalétique de de chaleur à...
  • Page 21: Caractéristiques

    NE JAMAIS LAISSER LE RADIATEUR SANS SURVEILLANCE ALORS QU’IL EST EN MARCHE OU QU’IL EST RACCORDÉ ® À UNE SOURCE D’ALIMENTATION. Caractéristiques Model # PT-150T-DFV PT-220T-DFV Classement: Btu/Hr 120,000 / 150,000 170,000 / 220,000 Consommation de Carburant: Gal/Hr 0.91 / 1.14 1.29 / 1.67 Capacité...
  • Page 22 NE JAMAIS LAISSER LE RADIATEUR SANS SURVEILLANCE ALORS QU’IL EST EN MARCHE OU QU’IL EST RACCORDÉ ® À UNE SOURCE D’ALIMENTATION. Les Instructions D’Assemblage Modèles: PT-150T-DFV / PT-220T-DFV Retirez l’appareil et tout le matériel Outils Nécessaires: d’emballage du carton. - Tournevis à tête étoilée (Phillips) - Clé...
  • Page 23 NE JAMAIS LAISSER LE RADIATEUR SANS SURVEILLANCE ALORS QU’IL EST EN MARCHE OU QU’IL EST RACCORDÉ ® À UNE SOURCE D’ALIMENTATION. Les Instructions D’Assemblage Modèles: PT-150T-DFV / PT-220T-DFV 1. Placer l’appareil de chauffage sur des chevalets de menuisier ou un établi pour faciliter l’assemblage.
  • Page 24: Fonctionnement

    NE JAMAIS LAISSER LE RADIATEUR SANS SURVEILLANCE ALORS QU’IL EST EN MARCHE OU QU’IL EST RACCORDÉ ® À UNE SOURCE D’ALIMENTATION. Fonctionnement Ravitaillement en Carburant: REMARQUE: Le kérosène doit uniquement être kérosène (1-k) Pour obtenir une performance optimale, il est conservé...
  • Page 25 NE JAMAIS LAISSER LE RADIATEUR SANS SURVEILLANCE ALORS QU’IL EST EN MARCHE OU QU’IL EST RACCORDÉ ® À UNE SOURCE D’ALIMENTATION. Fonctionnement Starting the Heater: (Ignition) Arrêt / Redêmarrage du Chauffage: Pour arrêter l’appareil, placez l’interrupteur 1. Remplir le réservoir avec du kérosène ou en position «...
  • Page 26: Entretien

    NE JAMAIS LAISSER LE RADIATEUR SANS SURVEILLANCE ALORS QU’IL EST EN MARCHE OU QU’IL EST RACCORDÉ ® À UNE SOURCE D’ALIMENTATION. Entretien Entreposage de Longue Durée: Service: Modèles 45-kFA / 70T-kFA: Ne jamais réparer un radiateur AVERTISSEMENT 1. Utilisez un siphon approuvé pour drainer le carburant qui est branché...
  • Page 27 NE JAMAIS LAISSER LE RADIATEUR SANS SURVEILLANCE ALORS QU’IL EST EN MARCHE OU QU’IL EST RACCORDÉ ® À UNE SOURCE D’ALIMENTATION. Entretien (Suite) Service (Suite): BOUGIE D’ALLUMAGE: PALES DE VENTILATEUR : Nettoyer et régler l’écartemetn entre les électodes Les pales doivent être nettoyées au moins toutes les 600 heures de fonctionement ou une fois par saison de chauffage, ou plus remplacer suivant le besoin, Aprés dépose de...
  • Page 28: Schéma De Câblage

    NE JAMAIS LAISSER LE RADIATEUR SANS SURVEILLANCE ALORS QU’IL EST EN MARCHE OU QU’IL EST RACCORDÉ ® À UNE SOURCE D’ALIMENTATION. Entretien (Suite) BUSES: Les buses doivent être nettoyées ou remplacées de la buse. Il peut être nécessaire de tremper au moins une fois par saison de chauffage.
  • Page 29: Dépannage

    NE JAMAIS LAISSER LE RADIATEUR SANS SURVEILLANCE ALORS QU’IL EST EN MARCHE OU QU’IL EST RACCORDÉ ® À UNE SOURCE D’ALIMENTATION. Guide de Dépannage Repérage du Numéro de Série: Le numéro de série se trouve sur une étiquette blanche apposée du côté droit du couvercle de l’appareil de chauffage.
  • Page 30: Vue Éclatée Des Pièces

    NE JAMAIS LAISSER LE RADIATEUR SANS SURVEILLANCE ALORS QU’IL EST EN MARCHE OU QU’IL EST RACCORDÉ ® À UNE SOURCE D’ALIMENTATION. Vue Éclatée des Pièces © 2014, Pinnacle Products International, Inc. Chauffage Dual Fusion Manuel de L’utilisateur...
  • Page 31: Liste Des Pièces

    NE JAMAIS LAISSER LE RADIATEUR SANS SURVEILLANCE ALORS QU’IL EST EN MARCHE OU QU’IL EST RACCORDÉ ® À UNE SOURCE D’ALIMENTATION. Liste des Pièces No. De Ref Description PT-150T-DFV PT-220T-DFV Enveloppe Avant 70-001-5000 70-001-5005 Chambre de Combustion 70-011-1000 70-011-1010 Enveloppe Supérieur 70-001-5010 70-001-5010 Déflecteur de la Chambre...
  • Page 32 NE JAMAIS LAISSER LE RADIATEUR SANS SURVEILLANCE ALORS QU’IL EST EN MARCHE OU QU’IL EST RACCORDÉ ® À UNE SOURCE D’ALIMENTATION. Liste des Pièces No. De Ref Description PT-150T-DFV PT-220T-DFV Conduite de Combustible de Retour 70-036-2100 70-036-2100 Bouchon de Réservoir de Combustible 70-006-0120 70-006-0120 Jauge de Combustible...
  • Page 33: Garantie

    NE JAMAIS LAISSER LE RADIATEUR SANS SURVEILLANCE ALORS QU’IL EST EN MARCHE OU QU’IL EST RACCORDÉ ® À UNE SOURCE D’ALIMENTATION. GARANTIE LIMITÉE Pinnacle Products International, Inc. garantit à Si Pinnacle Products International, Inc. détermine que l’acheteur au détail d’origine seulement que ce radiateur l’article est dans un état d’utilisation normale, ou n’est pas sera exempt de défauts de matériau et de fabrication défectueux, il sera retourné...
  • Page 34 © 2014 Pinnacle Products International, Inc. 668 Stony Hill Road #302 Yardley, PA 19067 USA • Toll Free (800)-641-6996 Fax: (215)-891-8461 • Web: www.pinnacleint.com • Email: info@pinnacleint.com...

This manual is also suitable for:

Protemp pt-220t-dfv

Table of Contents