Tip Selection - Pace TP-65 Operation & Maintenance Instructions Manual

Thermopik handpiece
Table of Contents

Advertisement

TRADITIONAL
1. Connect the 137cm (54 inch) length of air hose to the metal tube in
the back of the handpiece.
2. Insert a male quick connect hose mount fitting (P/N 1259-0087) to
the free end of the 137cm (54 inch) length of air hose.
3. Secure the air hose to the handpiece power cable with cable clips
(P/N 1321-0085-01).
4. Prepare a VisiFilter in the same manner as in steps 4 & 5 of the
"Quick Connect Method".

TIP SELECTION

Selection of the proper tip is essential for effective operation. Attempts to use
an improperly sized tip will result in unsatisfactory handpiece operation and
may result in lifted lands or board damage.
Table I details a partial listing of available tips. Contact your local authorized
PACE dealer for the latest Tips & Accessories Catalogue which details all
available tips.
TIP INSTALLATION
1. Carefully remove any installed vacuum cup from the TP-65 using the
tip tool and set aside.
2. Select the proper tip for your application. Refer to Table I.
3. Insert the tip shaft fully into the heater bore.
4. Using the tip tool, tighten the heater assembly set screw for a snug
fit. Do not over tighten.
5. Install the vacuum cup set aside in step #1 onto the vacuum pickup
rod. Utilize the tip tool to install the vacuum cup if the tip is hot.
The TP-65 tips must be kept properly tinned and free of oxidation to ensure
that optimum heat transfer will take place. Refer to the "Tip Preparation"
portion of this manual.