QUICK CONNECT METHOD
To set up your TP-65 for the quick connect operation, perform the following steps.
1. Attach a 2.5cm length (1 inch) of clear pvc air hose (P/N 1325-0003-
07) to the metal tube in the back of the handpiece.
2. To the other end of the 2.5cm length (1 inch) clear pvc air hose attach
a female quick connect hose mount fitting (P/N 1259-0086).
3. Prepare a quick connect air hose by inserting a male quick connect
hose mount fitting (P/N 1259-0087) into each end of a 137cm (54 inch)
length of air hose. (You may already have this piece if you have other
quick disconnect handpieces configured.)
4. Prepare a VisiFilter in the following manner:
a) Connect a 2.5cm (1 inch) length of air hose to each side of the
VisiFilter.
b) To the free end of the 2.5cm (1 inch) air
hose connected to the FLOW IN side of
the VisiFilter, insert a female quick
connect hose mount fitting (P/N 1259-
0086).
b) To the free end of the 2.5cm (1 inch) air
hose connected to the FLOW OUT side
of the VisiFilter, insert a male quick
connect hose mount fitting (P/N 1259-
0087).
c) Insert the end of the male quick connect
hose mount fitting (on VisiFilter FLOW
OUT side) into the power source AUTO
SNAP-VAC (or SNAP-VAC) Port.
5. Connect the male fitting of the 137cm (54 inch) length of air hose to
the female quick connect hose mount fitting on 2.5cm (1 inch) air hose
(connected to VisiFilter) for desoldering, or into the Controllable
PRESSURE Port for hot air jet operation.
When removing any air hose, turn and pull. Do not attempt to pull hose directly
off. Damage to or breakage of fitting or VisiFilter may occur. Use your TP-
65 ThermoPik with a clean VisiFilter element . Otherwise a deterioration in
performance or damage to the unit may occur.