TRIGger[:SEQuence]:LEVel:VIDeo <VideoTrigLevel>
This command defines the level of the video trigger.
Video trigger is available for time domain measurements (span = 0).
Parameters:
<VideoTrigLevel>
Example:
TRIGger[:SEQuence]:SLOPe <TriggerSlope>
This command selects the slope of the trigger signal.
The trigger slope applies to all trigger sources.
Parameters:
<TriggerSlope>
Example:
TRIGger[:SEQuence]:SOURce <TriggerSource>
This command selects the trigger source.
Parameters:
<TriggerSource>
Example:
13.6.2.5

Working with Traces

The following commands set up the trace and the various functions associated with it,
e.g. trace mathematics or the selection of the detector.
List of commands
CALCulate<1...2>:MATH<1...2>[:EXPRession][:DEFine]
User Manual 1321.1011.02 ─ 06.00
Range:
0 PCT to 100 PCT
*RST:
50 PCT
TRIG:LEV:VID 50PCT
Sets the trigger level to 50%.
POSitive | NEGative
*RST:
POSitive
TRIG:SLOP NEG
IMMediate | EXTernal | VIDeo | GATed
IMMediate
Selects Free Run measurements.
EXTernal
Selects an external trigger.
VIDeo
Selects the video trigger.
*RST:
IMMediate
For more information, see chapter "Setting the Sweep".
TRIG:SOUR EXT
Selects the external trigger input as source of the trigger signal.