Regularly check all components in the ducting (e.g. wall pipe, ex-
ternal grille, bends, elbows, etc.) to make sure air can move through
them and to ensure that they are working properly. Clean compon-
ents when necessary. Fluff deposits in the ducting system will pre-
vent the air from being extracted properly and, as a result, will stop
the tumble dryer from working properly.
If existing ducting is due to be used, it must be checked before be-
ing connected to the tumble dryer.
If multiple tumble dryers are to be installed on one exhaust air
duct, a non-return flap must be installed directly on the duct for each
tumble dryer.
If this requirement is not observed, the tumble dryers may be dam-
aged and their electrical safety could be affected.
The fluff filter must be cleaned on a regular basis.
Never operate the tumble dryer without the fluff filter or with a
damaged fluff filter. This could lead to malfunctions. Fluff can clog
the air channels, heating elements and ducting, which could result in
a fire.
Stop the tumble dryer immediately and replace the damaged fluff fil-
ter.
Do not install the tumble dryer in a room where there is a risk of
frost. At temperatures around freezing point, the tumble dryer may
not be able to operate properly.
The permitted room temperature is between 2 °C and 35 °C.
Warning and Safety instructions