Download Print this page

Mitsubishi Electric City Multi PLFY-P VCM-E3 Series Installation Manual page 6

Air-conditioners for building application, indoor unit

Advertisement

JKL
55 mm
12 mm
A
B
~220-240V
C
A
B
D
~220-240V
L N
C
TB2
L
D
C
C
C
C
M1
M2
S
1 2
TB5
TB15
1. Remove 2 screws to detach the electric component cover.
2. Route each cable through the wiring intake into the electric component box. (Procure
power supply cable and control cable locally.)
3. Securely connect the power supply cable and control cable to the terminal
blocks.
4. Secure the cables with clamps outside the electric component box.
5. Attach the electric component cover as it was.
Always install earth.
(Earth cable dia: Thicker than 1.6 mm)
bushing for tensile force. (PG connection or the like.)
A
Electric component cover
B
Electric component box
C
Entry for power supply cable
D
Entry for remote control cable and trans-
mission cable
E
Cable clamp
F
Power supply terminals (L, N,
)
(1) Take out the wireless junction cable that is supplied with the accessories.
(2) Route the indoor controller board connector (white) of the wireless junction cable
through the main unit BUSH in the direction indicated by the arrow. (Fig. 4-2)
(3) Route the wireless junction cable through the electric component box BUSH, and
(4) Secure the cables and wires with the clamp.
A
Wireless junction cable (Accessory)
B
Main unit BUSH
C
Electric component box
D
Electric component box BUSH
E
Clamp
F
Indoor controller board
IEC57, 245 IEC 53 or 227 IEC 53.
provided by the air conditioner installation.
A
Ground-fault interrupter
B
C
Indoor unit
D
Pull box
Warning:
G
Transmission terminals (M1, M2, S)
H
MA Remote controller terminal (1. 2)
I
Indoor controller
J
Remote control cable
K
Transmission cable
L
Power supply cable

Advertisement