General
Information
Thank you for purchasing your
Hydromatic
pump. To help
®
ensure years of trouble-free
operation,
please
following manual carefully.
Before Operation:
Read the following instructions
carefully. Reasonable care and
safe methods should be practiced.
Check
local
codes
requirements before installation.
Attention:
This manual contains important
information for the safe use of
this product.
Read this manual
completely before using this
product and refer to it often for
continued
safe
product
DO NOT THROW AWAY OR
LOSE THIS MANUAL. Keep it
in a safe place so that you may
refer to it often.
WARNING: Before handling
these pumps and controls,
always disconnect the power
first. Do not smoke or use
sparkable electrical devices or
flames in a septic (gaseous) or
possible septic sump.
Pump
Warning
IMPORTANT: Read all directions
before replacing any parts.
WARNING: Before handling
these pumps and controls, always
disconnect the power first.
2
Do not smoke or use sparkable
electrical devices or flames in a
septic (gaseous) or possible
septic sump.
Pump:
The
submersible pump family was
read
the
designed in accordance with
requirements
locations.
connected properly, will provide
years of trouble-free service. If
servicing is required, the repair
should be done by a Hydromatic
approved service center.
and
Application:
These pumps are designed for
on-site
discharge applications with a pH
ranging from 6 to 9, specific
gravities
viscosities ranging from 28 to 35
S.S.U., and temperatures up to
use.
140 degrees Fahrenheit.
Receiving Pump:
Pump should be checked on
arrival for possible concealed
shipping damage. Any damage
should be reported immediately
to delivery carrier. Claims for
damage must originate at the
receiving
shipping damage cannot be
processed at the factory.
Codes:
All local wiring codes must be
observed. Consult the local
inspector before installation to
avoid costly delays that can
occur due to rejection after job
is finished.
Pumps Not Operating or
in Storage:
Pumps with carbon ceramic seals
must have impellers manually
hazardous
location
for
hazardous
These
pumps,
residential
sewage
from
0.9
to
1.1,
end.
Claims
for
rotated (6 revolutions) after
setting non-operational for 3
months or longer and prior to
electrical start-up.
Seal Failure Probes:
All
hazardous
submersible pumps have two
factory-installed
detectors (seal failure probes).
They are in a normally open series
circuit in the seal chamber. Under
normal operating conditions the
circuit remains open. If the lower
seal leaks and moisture enters this
chamber, the moisture would
settle to the bottom of the
chamber and will complete the
circuit between the moisture
detectors.
This circuit must be connected to
a sensing unit and signaling
device. This is supplied in a
Hydromatic control panel.
NOTE: Failure to install such a
device negates all warranties by
Hydromatic pumps.
Heat Sensors:
All motors in this family have
heat sensors on or embedded in
the motor winding to detect
excessive heat. This prevents
damage to the motor. If the sensor
trips due to excessive winding
temperature, the starter in the
panel breaks power to the pump.
Once the sensor resets, the starter
is to be reset (automatic for FM)
for continued operation of the
pump. This circuitry is supplied in
a Hydromatic control panel. The
sensors are set to trip at 120
degrees Celsius.
NOTE: Failure to install such
circuitry would negate FM
approval and all warranties by
Hydromatic pumps.