Summary of Contents for Pentair Pool Products Hydromatic H3HX Series
Page 1
Installation and Service Manual SUBMERSIBLE PUMP WITH HAZARDOUS LOCATION MOTOR END Model H3HX (Class I, Division 1, Groups C & D): FM (Hazardous Location Motor End) NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system.
Pump: Heat Sensors: General hazardous location All motors in this family have Information submersible pump family was heat sensors on or embedded in designed in ac cor dance with the motor winding to detect requirements haz ard ous ex ces sive heat. This prevents Thank you for purchasing your locations.
Single phase pumps with capacitor not connect the power until after Pump start have a run and a start winding this test. each drawing a different current. Operations Clean all trash and sticks from To adequately protect these sump and connect pump to piping. windings with the appropriate A check valve must be installed heaters, consult the factory.
Page 4
TYPICAL FM ONLY SCHEMATICS TYPICAL SINGLE PHASE MOTOR CONNECTIONS PUMP MOTOR WHITE HEAT SENSORS 120 VAC, 5A BLACK SEAL PROBES 300 VAC, 20 MA FUSES CAPACITOR GREEN 330K 120 VAC START CAPACITOR SEE TYPICAL POWER CONTROL CIRCUITRY CORD CAPACITOR BELOW CONTROL PACK PANEL CORD...
WARNING: Before handling After removal from pump, Pump these pumps and controls, always reinstall wire nuts in cord and cap Operations dis con nect the pow er first. assembly and install protective cover. Do not smoke or use sparkable elec tri cal devices or flames in a 8.
Page 6
by using hands up through completely fill; leave oil about Pump rotor core. 1" below plug hole. Use only Maintenance Hydromatic sub mers ible oil or high grade trans form er oil in IMPORTANT: Use only butt this chamber. Re place plug; con nec tions on the wires.
Page 7
be used to ease its removal. sup ply house or can be obtained 12.Before refilling chamber with This kit will include a pusher from Hydromatic factory. oil, air test as described in to reassemble in re place ment replacing stator. 8.
H3HX Parts List For use with product built with USEM motor. ORDERING REPLACEMENT PARTS: Product improvements are made from time to time. The latest part design will be fur nished as long as it is in ter change able with the old part.When ordering re place ment parts, always furnish the fol low ing information: (1) pump serial num ber, (2) pump model and size, (3) part description, (4) part number, (5) im pel ler diameter (if ordering impeller), (6) quan ti ty required, and (7) shipping instructions.
STANDARD LIMITED WARRANTY HYDROMATIC ® warrants its products against defects in material and workmanship for a period of 12 months from the date of shipment from Hydromatic or 18 months from the manufacturing date, whichever occurs first - provided that such products are used compliance with the requirements of the Hydromatic catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive free non-corrosive liquids.
START-UP REPORT Distributor:__________________________________________________ Order No.: _________________________ Installing Contractor: _________________________________________ Phone: ____________________________ Sales Contact: ______________________________________________ Phone: ____________________________ Customer: ______________________________________________________________________________________ Location: _______________________________________________________________________________________ 1. SYSTEM INFORMATION Size of Wet Well:_______________________________________Manufacturer: _____________________________ Discharge from Bottom of Basin: ________________________Discharge Location:________________________ Inlet from Bottom of Basin: _____________________________Inlet Location: _____________________________ Type of Check Valves: __________________________________Type of Piping: ____________________________ Does System Have Suction Gauges? ❑...