General Information - Pentair Pool Products Hydromatic S3HVX Installation And Service Manual

Hazardous location submersible pump
Table of Contents

Advertisement

General
Information
Thank you for purchasing your
Hydromatic
pump. To help
®
ensure years of trouble-free
operation,
please
following manual carefully.
Before operation:
Read the following instructions
carefully. Reasonable care and
safe methods should be practiced.
Check
local
codes
requirements before installation.
Attention:
This manual contains important
information for the safe use of
this product.
Read this manual
completely before using this
product and refer to it often for
continued
safe
product
DO NOT THROW AWAY OR
LOSE THIS MANUAL. Keep it
in a safe place so that you may
refer to it often.
Unpacking Pump:
Remove pump from carton. When
unpacking
unit,
concealed damage. Claims for
damage must be made at the
receiving end through the delivery
carrier.
Damage
processed from the factory.
WArNiNg: Before handling
these pumps and controls,
always disconnect the power
first. Do not smoke or use
sparkable electrical devices or
flames in a septic (gaseous) or
possible septic sump.
2
Pump:
The
submersible pump family was
designed in accordance with
requirements
locations.
connected properly, will provide
years of trouble-free service. If
read
the
servicing is required, the repair
should be done by a Hydromatic
approved service center.
Pumps in Storage or Not
operating:
Pumps with carbon ceramic seals
and
must have impellers manually
rotated (6 revolutions) after
setting non-operational for 3
months or longer and prior to
electrical start-up.
Pumps with tungsten carbide seals
must have impellers manually
rotated (6 revolutions) after
setting non-operational for 3
weeks or longer and prior to
use.
electrical start-up.
Seal Failure Probes:
All
submersible pumps have two
factory
detectors (seal failure probes).
They are in a normally open series
check
for
circuit, in the seal chamber. Under
normal operating conditions, the
circuit remains open. If the lower
seal leaks and moisture enters this
cannot
be
chamber, the moisture would
settle to the bottom of the
chamber and will complete the
circuit between the moisture
detectors.
This circuit must be connected to
a sensing unit and signaling
device (UL listed system has a
continuity test circuit). This is
supplied in a Hydromatic built
control panel.
hazardous
location
for
hazardous
These
pumps,
hazardous
location
installed
moisture
Note: Failure to install such a
device negates all warranties by
Hydromatic.
Heat Sensors:
All motors in this family have
heat sensors on or embedded in
the motor winding to detect
excessive heat. This prevents
damage to the motor. If sensor
trips due to excessive winding
temperature, starter in panel
breaks power to the pump. Once
sensor resets, the starter is to be
manually reset for UL and
automatic reset for FM for
continued operation of the pump.
This circuitry is supplied in a
Hydromatic control panel.
The sensors are set to trip at
120°C (248°F).
Note:
Failure
to
such circuitry would negate
UL and FM approvals and all
warranties by Hydromatic.
Power Cords:
The power cord and heat sensor
seal failure cord are potted into
the connection box cap. The cords
must not be spliced.
Note: each cable has a
green lead. this is the ground
wire and must be grounded
properly per N.e.C. and/or
local codes. Cords should be
inspected for abnormal wear
and replaced accordingly.
overload Heaters:
If the Hydromatic electrical panel
is not used, starters with 3 leg
overload relay must be supplied on
3 phase pumps. Each leg is to
have an identical heater sized in
accordance with the nameplate
amps on the motor housing. The
install

Advertisement

Table of Contents