Pentair Pool Products HYDROMATIC HPGX200 Installation And Service Manual

Pentair Pool Products HYDROMATIC HPGX200 Installation And Service Manual

Hazardous location submersible grinder pump

Advertisement

Quick Links

Installation and Service Manual
HAZARDOUS LOCATION
SUBMERSIBLE GRINDER PUMP
Model HPGX200
(Class I, Division 1, Groups C & D): FM
NOTE! To the installer: Please make sure
you provide this manual to the owner of
the equipment or to the responsible party
who maintains the system.
04/11
Item # E-03-438
Part # 5625-438-1
© 2011 Pentair Pump Group, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HYDROMATIC HPGX200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pentair Pool Products HYDROMATIC HPGX200

  • Page 1 Installation and Service Manual HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP Model HPGX200 (Class I, Division 1, Groups C & D): FM NOTE! To the installer: Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system.
  • Page 2: General Information

    Do not smoke or use sparkable rotated (6 revolutions) after General electrical devices or flames in a setting non-operational for 3 Information septic (gaseous) or possible months or longer and prior to septic sump. electrical start-up. Thank you for purchasing your Pump: Seal Failure Probes: Hydromatic...
  • Page 3: Pump Installation

    Power Cords: CAUTION: Make sure that Installing Pump in Sump: the ground wire is securely The power cord and heat sensor Before installing pump in sump, connected and that the unit seal failure cord are potted into lay it on its side and rotate properly grounded the connection box cap.
  • Page 4: Pump Operations

    Heat Sensor and Seal 1. If pump is 3 phase, the rotation Pump Failure Connections: of the impeller must first be Maintenance checked. Lift pump from If a Hydromatic control panel is sump, lay it down, and quickly used, terminal blocks turn pump on and then off.
  • Page 5 warranty and not used in a 5. Check pump proper 8. Clean all parts thoroughly hazardous location can be field rotation before returning to before proceeding with serviced reputable normal service. assembly. Make sure spring serviceman. When any field pin (21) is inserted into servicing is performed on a pump, impeller (17).
  • Page 6 CAUTION: Do not use any old 2. Drain all oil from upper assembly (32). If when rotated seal parts. Replace all parts housing. Remove drain plug they feel rough, replace. When with new pieces. Mixing old and (11) in bottom of bearing reinstalling bearings, new parts will cause immediate...
  • Page 7: Pump Troubleshooting

    Pump is noisy. If the cause of the trouble cannot Pump be determined and corrected as 1. Defective bearings Troubleshooting outlined above, contact your 2. No axial clearance between nearest factory representative. impeller and volute 3. No axial clearance between Below is a list of troubles and radial cutter and cutter ring their probable causes.
  • Page 8: Parts List

    HPGX200 Parts List ORDERING REPLACEMENT PARTS: Product improvements are made from time to time. The latest part design will be furnished as long as it is interchangeable with the old part.When ordering replacement parts, always furnish the following information: (1) pump serial number, (2) pump model and size, (3) part description, (4) part number, (5) impeller diameter (if ordering impeller), (6) quantity required, and (7) shipping instructions.
  • Page 9 HPGX200...
  • Page 10: Standard Limited Warranty

    STANDARD LIMITED WARRANTY HYDROMATIC ® warrants its products against defects in material and workmanship for a period of 12 months from the date of shipment from Hydromatic or 18 months from the manufacturing date, whichever occurs first - provided that such products are used compliance with the requirements of the Hydromatic catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive free non-corrosive liquids.
  • Page 12: Start-Up Report

    START-UP REPORT Distributor:__________________________________________________ Order No.: _________________________ Installing Contractor: _________________________________________ Phone: ____________________________ Sales Contact: ______________________________________________ Phone: ____________________________ Customer: ______________________________________________________________________________________ Location: _______________________________________________________________________________________ 1. SYSTEM INFORMATION Size of Wet Well:_______________________________________Manufacturer: _____________________________ Discharge from Bottom of Basin: ________________________Discharge Location:________________________ Inlet from Bottom of Basin: _____________________________Inlet Location: _____________________________ Type of Check Valves: __________________________________Type of Piping: ____________________________ Does System Have Suction Gauges? ❑...

Table of Contents