JX3-BN-EC User Manual
Parameter
RF field, amplitude-modulated
Frequency band
Test field strength
ESD
Discharge through air
Test peak voltage 6 kV
Contact discharge
Test peak voltage 6 kV
Tab. 5: Immunity to interference
Parameter
RF field, asymmetric, amplitude modulated
Frequency band
Test voltage
Source impedance
Bursts
Test voltage
Repetition frequency
Surge voltages, symmetric, line to cable
Series-mode interference
Surge voltages, asymmetric, line to earth
Common-mode interference tr/th 1.2/50 µs
Tab. 6: DC power supply inputs and outputs
Values
80 MHz ... 2 GHz
10 V/m
AM 80 % with 1 kHz
Criterion A
8 kV
4 kV
Criterion A
Values
0.15 ... 80 MHz
10 V
AM 80 % with 1 kHz
150 Ω
Criterion A
2 kV
tr/tn 5/50 ns
5 kHz
Criterion A
tr/th 1.2/50 µs
0.5 kV
1 kV
Technical specifications | 4
Standards
DIN EN 61131-2
DIN EN 61000-6-2
DIN EN 61000-4-3
DIN EN 61131-2
DIN EN 61000-6-2
DIN EN 61000-4-2
Standards
DIN EN 61131-2
DIN EN 61000-6-2
DIN EN 61000-4-6
DIN EN 61131-2
DIN EN 61000-6-2
DIN EN 61000-4-4
DIN EN 61131-2
DIN EN 61000-6-2
DIN EN 61000-4-5
DIN EN 61131-2
DIN EN 61000-6-2
DIN EN 61000-4-5