Summary of Contents for Swegon SILVER C RX 100

  • Page 1 GB.SILVERF120.181005 Installation instructions for the SILVER C RX/CX version F, size 100/120 The document was originally written in Swedish. www.swegon.com We reserve the right to alter specifications.
  • Page 2: Table Of Contents

    1.11 Electrical Connections........22 1.12 Installation of pipework package (SILVER C CX only) ............23 2. Dimensions ..........23 2.1 SILVER C RX 100/120 ........... 23 2.2 SILVER C CX 100/120 ........... 24 www.swegon.com We reserve the right to alter specifications.
  • Page 3: Installation

    Section 1.7 for installation particulars. side of the air handling unit. Refer to the particulars on the product identification plate when you contact Swegon. For other dimensions and weights, see Section 2.1. The air handling unit is supplied in packaged condition.
  • Page 4: Lifting

    1.6.2 With a crane 1.6.2.1 Complete units NOTE! A line spreader must NOTE! A line spreader must be used! be used! NOTE! High centre of gravity! Other sections Rotary heat exchanger (SILVER C RX only). www.swegon.com We reserve the right to alter specifications.
  • Page 5: Heat Exchanger Section, Supplied Split Into Two Casing Sections And Rotor (Silver C Rx Only)

    GB.SILVERF120.181005 1.6.2.2 Heat exchanger section, supplied split into two casing sections and rotor (SILVER C RX only) NOTE! A line spreader must be used! Upper casing section Lower casing section www.swegon.com We reserve the right to alter specifications.
  • Page 6 Remove the wooden stud Guard plate NOTE! Carefully raise the rotor so that it will not be damaged! Make sure that the lifting device rests against the protecting plate at the top edge. www.swegon.com We reserve the right to alter specifications.
  • Page 7: To Assemble The Heat Exchanger Unit Section, If Required (Silver C Rx Only)

    If the heat exchanger unit section is supplied as one unit, go on to Section 1.8. 1.7.1 Alternative 1 Remove the upper shaft bracket and the sealing plate (2x) Shaft mounting brackets Lower casing section www.swegon.com We reserve the right to alter specifications.
  • Page 8 NOTE! IMPORTANT! The smooth side of the rotor hub (with- out holes) should face the pressing roller! Be careful not to damage the rotor! Pressing roller Hub side Mount the upper shaft bracket and the sealing plate (2x) www.swegon.com We reserve the right to alter specifications.
  • Page 9 2 x 6 2 x 4 Fix the upper casing section to the lower casing section with the bolts supplied, screwing them into the pre-fitted rivet nuts (a total of 20 pcs.). www.swegon.com We reserve the right to alter specifications.
  • Page 10 Move the motor + mounting bracket back to their original positions. Secure the motor + mounting bracket with bolts (6 bolts). See also Section 1.7.3 Common for Alternatives 1 and 2 www.swegon.com We reserve the right to alter specifications.
  • Page 11: Alternative 2

    1.7.2 Alternative 2 Remove the upper shaft bracket and the sealing plate (2x) Shaft mount- ing brackets Dismantle the heat exchanger motor + mounting bracket (6 bolts). Remove the sealing plate and tube. www.swegon.com We reserve the right to alter specifications.
  • Page 12 NOTE! IMPORTANT! The smooth side of the rotor hub (with- out holes) should face the pressing roller! Be careful not to damage the rotor! Pressing roller Hub side Mount the upper shaft bracket and the sealing plate (2x) www.swegon.com We reserve the right to alter specifications.
  • Page 13 Slacken off the two screws holding the motor + mounting bracket. Move the motor + mounting brack- et to the position shown in the illustration. Secure the motor + mounting bracket with bolts (6 bolts). www.swegon.com We reserve the right to alter specifications.
  • Page 14 Fix the upper casing section to the lower casing section with the bolts supplied, screwing them into the pre-fitted rivet nuts (a total of 16 pcs.). See also Section 1.7.3 Common for Alternatives 1 and 2 www.swegon.com We reserve the right to alter specifications.
  • Page 15: Common For Alternatives 1 And 2

    Slightly back off the locking bolts. Do not dismantle the shaft bracket. Adjust the inclination of the rotor by means of the adjusting bolts. Tighten the adjusting bolts equally. When you have adjusted the inclination, tighten the locking bolts. www.swegon.com We reserve the right to alter specifications.
  • Page 16: Sealing Plates/Purging Sector

    Slip the vinyl-coated fabric seal of the rotor (blue) over the rim all the way around on both sides of the rotor. Tension the pressing roller against the rotor hub until you no longer can roll the pressing roller with your hand. www.swegon.com We reserve the right to alter specifications.
  • Page 17: Sealing

    (front and rear). Apply appropriate sealing compound/ putty around the sealing plate of the rotor shaft (2 plates). www.swegon.com We reserve the right to alter specifications.
  • Page 18: Version And Fan Arrangement

    Fan arrangement 1 Fan arrangement 2 Fan arrangement 4, Fan arrangement 4, supply air – upper level supply air - lower level Left-hand version Outdoor air Supply air Extract air Exhaust air www.swegon.com We reserve the right to alter specifications.
  • Page 19: The Docking Of Unit Sections

    You can then tighten the screws from the opening of the duct connection. NOTE! You do not need to remove the fan assemblies completely! www.swegon.com We reserve the right to alter specifications.
  • Page 20: Fixation, Rear Of The Unit

    You can then tighten the screws from the opening of the duct connection. N.B.! You do not need to remove the fan assemblies completely! www.swegon.com We reserve the right to alter specifications.
  • Page 21: Duct Connection

    The air handling unit’s connection frames are rectangular and can be jointed to ducts by means of slip-clamps. The ducts should be insulated according to local regula- tions and customary trade standards. www.swegon.com We reserve the right to alter specifications.
  • Page 22: Electrical Connections

    1.12 Installation of pipework package (SILVER C CX only) For details on how to install the pipework package, see separate instructions for the TBXZ-42 pipework package. www.swegon.com We reserve the right to alter specifications.
  • Page 23: Dimensions

    GB.SILVERF120.181005 2. Dimensions 2.1 SILVER C RX 100/120 1048 1000 1048 3186 * The air handling unit is supplied without end connection panel if a duct accessory housed in an insulated casing will be connected. The AHU can also be supplied with full face end connection panel (accessory).
  • Page 24: Silver C Cx 100/120

    2500 1720 4494-4990 Individual weights Filter section SILVER C 100/120: 402-540 kg/section. Fan section SILVER C 100: 644-720 kg/section. SILVER C 120: 744-829 kg/section. Heat exchanger section SILVER C 100/120: 1101-1126 kg/section. www.swegon.com We reserve the right to alter specifications.