Troubleshooting - Lavit LB115 Series Troubleshooting Manual

Hide thumbs Also See for LB115 Series:
Table of Contents

Advertisement

Potential problems and solutions.
Condition
Water dripping
After the dispensing of a sparkling beverage or sparkling
continuously
water several drops may occur as the sparkling water in the
from the
water line heats up and expands. This is normal.
dispense area.
Continuously dripping water is caused by foreign material
lodged in the soda water solenoid. Remove the soda water
solenoid per the instructions on Page xx and disassemble
the solenoid to remove any trapped material.
Leaking water
Possible leak issues:
from the rear
of the unit.
First – Check the still water drain plug and then check the inlet
water line. If those connections are dry and not the source of
the water leak, remove the top cover of the unit.
Inspect the connections on the top of the water tanks.
Remove the ozone generator to view all connections. Ensure
all fittings are tight and dry. Inspect the area around the top
insulation seam towards the left side panel. If there is wetness
in that area the leak may be from the soda tank seal.
Other possible sources of a leak are the soda pump inlet
fitting, the inlet solenoid, or the cold tank drain connection.
To inspect these areas, remove the back panel per the
instructions of Page17.
Inspect the soda pump inlet fitting for leak at the quick
connect insert. Inspect the connections to the inlet
solenoid. If those connections show no evidence of leaking
and water is captured in the area at the bottom of the cold-
water tank, the water drain connection to the tank may be
the cause of the leak. Remove the insulation from around
the water tank drain pipe and inspect.
Other possible sources of leaks are the still water and
recirculation pump connections and the cooling coil
connection running to and from the compressor and
condenser.

Troubleshooting

Possible Solution
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents