No Soda Water - Gas Only - Lavit LB115 Series Troubleshooting Manual

Hide thumbs Also See for LB115 Series:
Table of Contents

Advertisement

Issue:
When the user selects soda water or a soda beverage no soda water is
dispensed just CO2 gas. This mayhappen all the time or on occasion.
Solution:
The soda tank is not refilling properly. There may be an air lock in the inlet
water line to the soda tank which the soda pump cannot overcome.
This usually happens on the installation of a unit when the tech turns the CO2
gas on before allowing the soda pump to start pumping water into the soda
tank. To resolve:
1.
Turn off the regulator
2.
Relieve all gas pressure thru the purge v a l v e
3.
Turn off and restart u n i t
4.
Dispense a full cup of cold-water
5.
Let the soda pump refill the tank (5 to 7 minutes)
6.
Turn on CO2.
7.
Before going on with trouble shooting try the above process once
more.
8.
If this does not correct the issue follow trouble shooting the soda
circuit on pages
No Soda Water – Gas Only
10
18-11-26-REV-A