Water Stream Calibration

EACH LAVIT BEVERAGE DISPENSER INSTALLED IN A CUSTOMER LOCATION SHOULD
BE CALIBRATED DURING THE INSTALLATION PROCESS TO ENSURE THAT PROPER
WATER AND BEVERAGE VOLUMES ARE DISPENSED. The Lavit
Beverage Capsule is sized to deliver 12-ounce beverages. It is important to deliver 12-
ounce beverages to maximize customer satisfaction with the beverage taste. Too little
water will produce overly sweet and intense beverage flavor. Too much water will
deliver weak and watery beverages.
It is critical that 12-ounce beverages be served each time. To properly calibrate the Lavit
Dispenser, three water streams must be calibrated: mix, still, and sparkling. During the
calibration process 12 ounces of water should be drawn from the dispenser for each
calibration. The unit's software determines the amount of time it takes for the 12 ounces
to be dispensed for each stream. The software then sets the proper time sequence to
deliver 7 and 12-ounce water servings and 12-ounce beverage servings.
The entire calibration process should take no more than five (5) minutes.
Required Materials and Tools
Measuring Cup or Beaker – marked for 12 oz. or 355 ml
Optional weight Scale – (Food scales are available in most department stores such as
Wal- Mart or Target)
Calibration Instructions
1. Open the mix chamber and remove the blue capsule tray. Close
2.
At initial startup, all the water lines should be first purged of air. Enter the WATER
SETUP screen from the SERVICE MENU screen. Your WATER SETUP screen
should be as below.
20
the chamber.