Power Connector (X1) - ABB EDS500 Series Manual

Hide thumbs Also See for EDS500 Series:
Table of Contents

Advertisement

Connections
Pin allocation serial interface RS-485 half duplex (RJ-12)
6
Pin allocation serial interface RS-485 full duplex (RJ-12)
6
4.7.5

Power connector (X1)

The EDS500 devices are equipped with a wide range power supply for voltages between 24
and 60 Volts DC (power consumption see device label). The connector is a 4-pin Phoenix plug
with screw terminals.
Power supply input (X1)
Operating voltage
Power consumption (typical)
Current demand (peak)
Plug type
Reverse polarity protection
Circuit classification
Galvanic isolation
Overvoltage protection
Electrical fast transient / Burst, IEC 61000-4-4 4 kV line to earth, 2 kV line to line (level 4), cri-
Surge 1.2/50 µs, IEC 61000-4-5
Conducted, common mode disturbances
in the frequency range 0 Hz to 150 kHz,
IEC 61000-4-16
Conducted emissions - asymetrical DC ports,
common mode (0.15 MHz to 30 MHz)
34
RS-485 half duplex / 2-wire
Pin
1
2
3
4
1
5
6
RS-485 full duplex / 4-wire
Pin
1
2
3
4
1
5
6
Signal
B (-)
GND
A (+)
Signal
B (-)
B (-)
GND
A (+)
A (+)
24... 60 V DC -20%... +20%
specific for device, see device label
specific for device, see device label
Phoenix Contact MSTBT 2.5/4-ST
yes
SELV (acc. IEC 60950-1)
1.5 kV isolation voltage
line to earth ±4 kV, line to line ±2 kV
terion A
4 kV line to earth, 2 kV line to line (level 4), cri-
terion A
30 V continuous disturbance/ 300 V short
duration disturbance (level 4), criterion A
EN 55032/ CISPR 32 class A
IEC 61000-6-4
Device description
Direction
bi-directional
-
bi-directional
Direction
Input
Output
-
Input
Output
1KGT150966 V000 1